TT336: Current / milliVolt Input, DC Power Transmitter
Product short description:
- Multi-range ±20mA or ±500mV input
- Universal current/voltage output
- 12-32V DC power
DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring.
Click here to watch a short video highlighting the TT330 Series.
- Description
- Features & Benefits
- Tech Papers
- Specs & Data Sheets
- Software
- Accessories
- Additional information
DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring.
High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors.
Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.
Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.
Performance Specifications
IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends the use of their USB-ISOLATOR when configuring a TT330 Series transmitter.
USB Interface
USB Connector: USB Mini-B type socket, 5-pin
USB Data Rate: 12Mbps. USB v1.1 and 2.0 compatible
USB Transient Protection: Transient voltage suppression on power and data lines
Maximum Cable Length: 5.0 meters
Driver:Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system
Input
Default Configuration/Calibration:
Input: 4 to 20mA, medium filter
Output: 4 to 20mA
Input Ranges and Accuracy:
Range Accuracy
±500mV ±0.05% of span
0 to 500mV ±0.05% of span
±20mA ±0.05% of span
0 to 20mA ±0.05% of span
4 to 20mA ±0.05% of span
0 to 11.17mA (for AC sensor) ±0.05% of span
±1mA ±0.05% of span
Error includes the effects of repeatability, terminal point conformity, and linearization.
Ambient Temperature Effect: Better than ±80ppm/°C (±0.008%/°C)
Zero Scaling Adjust: 0 to 95% of range, typical
Full Scale Adjust: 5 to 100% of full scale range, typical
Input Over-Voltage Protection: Bipolar Transient Voltage Suppressers (TVS), 5.6V clamp level typical
Input Resolution:
Bipolar input: 1 part in 50000 (±25000)
Unipolar input: 1 part in 25000
Input Impedance:
Current input: 24.9 ohms
Voltage input: 15M ohms
Input Filter: Selectable digital filtering settings (none, low, medium, and high)
Input Filter Bandwidth:
Normal mode plus digital filtering within the ADC
Bandwidth (-3dB) varies with digital filter setting from 4Hz without filtering to 0.33Hz with high filtering.
Noise Rejection:
Normal mode @ 60Hz: >4dB (no filter), >80dB (high filter)
Common mode @ 60Hz: >90dB (no filter), >120dB (high filter)
Output
Output Range:
Range Over-Range Resolution
±10V ±10.5V 1 part in 62415
±5V ±5.V 1 part in 31208
0 to 10V –0.5527 to +10.5V 1 part in 59240
0 to 5V –0.27634 to +5.25V 1 part in 60262
±20mA ±21mA 1 part in 62259
0 to 20mA –1.1054 to 21mA 1 part in 59596
4 to 20mA –1.1054 to 21mA 1 part in 46877
Output Load:
Voltage output: 1K ohms minimum
Current output: 0-550 ohms
Output Response Time (for step input change)
Time to reach 98% of output value (typical)
TB1 (±20mA) TB2 (±500mV)
No filter 10 milliseconds 15 milliseconds
Low filter 34 milliseconds 45 milliseconds
Medium filter 136 milliseconds 120 milliseconds
High filter 1168 milliseconds 1072 milliseconds
Output Ripple: Less than ±0.1% of output span
Output Ambient Temperature Drift: Better than ±80ppm/°C (±0.0080%/°C)
Environmental
Operating temperature: -40 to 80°C (-40° to 176°F)
Storage temperature: -40 to 85°C (-40 to 185°F)
Relative humidity: 5 to 95% non-condensing
Power requirement: 12-32V DC SELV (Safety Extra Low Voltage), 1.3W maximum
Isolation: 1500V AC peak. 250V AC (354V DC) continuous isolation between input, output, and power (3-way)
Shock and Vibration Immunity:
Vibration: 4g, per IEC 60068-2-6
Shock: 25g, per IEC 60068-2-27
Approvals: CE compliant. Designed for UL/cUL Class I Division 2 Groups ABCD. ATEX / IECEx certified Zone 2. II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C
Electromagnetic Compatibility (EMC) Compliance:
Radiated Emissions: BS EN 61000-6-4, CISPR 16
RFI: BS EN 61000-6-2, IEC 61000-4-3
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6
ESD: BS EN 61000-6-2, IEC 61000-4-2
EFT: BS EN 61000-6-2, IEC 61000-4-4
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5
Physical
General: General-purpose enclosure designed for mounting on 35mm “T-type” DIN rail
Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure
I/O Connectors: Removable plug-in terminal blocks rated for 12A/250V; AWG #26-12, stranded or solid copper wire
Dimensions: 17.5 x 114.5 x 99.0 mm (0.7 x 4.51 x 3.90 inches)
Shipping Weight: 0.22 kg (0.5 pounds) packed
- Easy setup and digital calibration via USB with Windows configuration software
- Single unit supports unipolar and bipolar input ranges up to ±20mA or ±500mV DC
- Compatible with 0-20A AC sensor input
- Universal output connections support ranges up to ±21mA or ±10.5V DC without rewiring
- Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
- High accuracy, linearity, stability, and reliability
- User-selectable filtering (low, medium, high)
- Adjustable response time (10ms to 1200ms)
- Supports reverse-acting (inverse) output
- Bus power, local power, or both
- Redundant power ready (rail/local)
- 1500V input isolation, 3-way (power, input, output)
- Shock (50g) and vibration (5g) resistant
- Mounts on Type T DIN-rail
- Wide ambient operation (-40 to 80°C)
- CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals
-
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
TTBus-Kit: DIN Rail Bus Power Connector
- One kit supports multiple SP Series Splitters or DT and TT Series transmitters.
$30Select options -
TTC-SIP: Software
- Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
- Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
- Easy setup and digital calibration via USB with Windows configuration software.
- Download the configuration software only - from the Software Tab
$170Select options -
USB Isolator
- USB-powered, USB 2.0 and 1.1 compatible
- 1500V AC / 2100V DC isolation
- No drivers required
$110Select options
Additional information
Weight | 8 oz |
---|---|
Dimensions | 4.51 × 0.5 × 3.9 in |
Part Number | TT336-0700: Four-wire transmitter |
Configuration | Agility Mobile App, Factory Calibration, USB Configuration, Windows Software Configuration |
Product Series | TT330 Series |
-
Description
DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring.
High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors.
Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.
Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.
Performance Specifications
IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends the use of their USB-ISOLATOR when configuring a TT330 Series transmitter.
USB Interface
USB Connector: USB Mini-B type socket, 5-pin
USB Data Rate: 12Mbps. USB v1.1 and 2.0 compatible
USB Transient Protection: Transient voltage suppression on power and data lines
Maximum Cable Length: 5.0 meters
Driver:Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating systemInput
Default Configuration/Calibration:
Input: 4 to 20mA, medium filter
Output: 4 to 20mAInput Ranges and Accuracy:
Range Accuracy
±500mV ±0.05% of span
0 to 500mV ±0.05% of span
±20mA ±0.05% of span
0 to 20mA ±0.05% of span
4 to 20mA ±0.05% of span
0 to 11.17mA (for AC sensor) ±0.05% of span
±1mA ±0.05% of span
Error includes the effects of repeatability, terminal point conformity, and linearization.Ambient Temperature Effect: Better than ±80ppm/°C (±0.008%/°C)
Zero Scaling Adjust: 0 to 95% of range, typical
Full Scale Adjust: 5 to 100% of full scale range, typical
Input Over-Voltage Protection: Bipolar Transient Voltage Suppressers (TVS), 5.6V clamp level typical
Input Resolution:
Bipolar input: 1 part in 50000 (±25000)
Unipolar input: 1 part in 25000
Input Impedance:
Current input: 24.9 ohms
Voltage input: 15M ohms
Input Filter: Selectable digital filtering settings (none, low, medium, and high)
Input Filter Bandwidth:
Normal mode plus digital filtering within the ADC
Bandwidth (-3dB) varies with digital filter setting from 4Hz without filtering to 0.33Hz with high filtering.
Noise Rejection:
Normal mode @ 60Hz: >4dB (no filter), >80dB (high filter)
Common mode @ 60Hz: >90dB (no filter), >120dB (high filter)Output
Output Range:
Range Over-Range Resolution
±10V ±10.5V 1 part in 62415
±5V ±5.V 1 part in 31208
0 to 10V –0.5527 to +10.5V 1 part in 59240
0 to 5V –0.27634 to +5.25V 1 part in 60262
±20mA ±21mA 1 part in 62259
0 to 20mA –1.1054 to 21mA 1 part in 59596
4 to 20mA –1.1054 to 21mA 1 part in 46877Output Load:
Voltage output: 1K ohms minimum
Current output: 0-550 ohmsOutput Response Time (for step input change)
Time to reach 98% of output value (typical)
TB1 (±20mA) TB2 (±500mV)
No filter 10 milliseconds 15 milliseconds
Low filter 34 milliseconds 45 milliseconds
Medium filter 136 milliseconds 120 milliseconds
High filter 1168 milliseconds 1072 millisecondsOutput Ripple: Less than ±0.1% of output span
Output Ambient Temperature Drift: Better than ±80ppm/°C (±0.0080%/°C)Environmental
Operating temperature: -40 to 80°C (-40° to 176°F)
Storage temperature: -40 to 85°C (-40 to 185°F)
Relative humidity: 5 to 95% non-condensing
Power requirement: 12-32V DC SELV (Safety Extra Low Voltage), 1.3W maximum
Isolation: 1500V AC peak. 250V AC (354V DC) continuous isolation between input, output, and power (3-way)
Shock and Vibration Immunity:
Vibration: 4g, per IEC 60068-2-6
Shock: 25g, per IEC 60068-2-27
Approvals: CE compliant. Designed for UL/cUL Class I Division 2 Groups ABCD. ATEX / IECEx certified Zone 2. II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C
Electromagnetic Compatibility (EMC) Compliance:
Radiated Emissions: BS EN 61000-6-4, CISPR 16
RFI: BS EN 61000-6-2, IEC 61000-4-3
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6
ESD: BS EN 61000-6-2, IEC 61000-4-2
EFT: BS EN 61000-6-2, IEC 61000-4-4
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5Physical
General: General-purpose enclosure designed for mounting on 35mm “T-type” DIN rail
Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure
I/O Connectors: Removable plug-in terminal blocks rated for 12A/250V; AWG #26-12, stranded or solid copper wire
Dimensions: 17.5 x 114.5 x 99.0 mm (0.7 x 4.51 x 3.90 inches)
Shipping Weight: 0.22 kg (0.5 pounds) packed -
Features & Benefits
- Easy setup and digital calibration via USB with Windows configuration software
- Single unit supports unipolar and bipolar input ranges up to ±20mA or ±500mV DC
- Compatible with 0-20A AC sensor input
- Universal output connections support ranges up to ±21mA or ±10.5V DC without rewiring
- Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
- High accuracy, linearity, stability, and reliability
- User-selectable filtering (low, medium, high)
- Adjustable response time (10ms to 1200ms)
- Supports reverse-acting (inverse) output
- Bus power, local power, or both
- Redundant power ready (rail/local)
- 1500V input isolation, 3-way (power, input, output)
- Shock (50g) and vibration (5g) resistant
- Mounts on Type T DIN-rail
- Wide ambient operation (-40 to 80°C)
- CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals
-
Tech Papers
How to Wire a 2 or 4-Wire Current Input Module Application NoteApplication Note: Current Input Wiring: 2-Wire & 4-Wire TT236 / SP236 / DT236 2/3-Wire Transmitters & Splitters TT336 / SP336 / DT336 4-Wire Transmitters & Splitters Featured Products: DT236: Current / milliVolt Input Two-Wire Dual Transmitter DT336: Current / Voltage Input Four-Wire Dual Transmitter SP236: Two-Wire Current / milliVolt Input Signal Splitter SP336: Four-Wire Current...How to Re-transmit and Isolate 4-20mA Signals from Remotely-Mounted 3-Wire Gas Detection Sensors Application NoteDefining the Problem: Typically, signals from 3-wire remote sensors monitoring combustible and toxic gases are transmitted directly to the remote gas monitor or controller. However, there are cases when it’s desirable to send the signal to more than one destination. This can either be accomplished by re-transmitting the existing signal to additional locations or by...How to Select the Right Isolator Application NoteThe Ins and Outs of Isolation: A Guide to Selecting the Right Isolator Acromag manufactures a variety of isolators to provide a cost-effective solution for many applications. The primary function of the isolator is to eliminate ground loops that may exist between two or more instruments. A classical application isolates the control room equipment (computers,...How to Choose a 4-20mA Isolator Application NoteVery often the simple task of choosing an isolator requires more than just comparing the number of channels and the cost per point. To help you with this exercise, here are a few concepts to know when specifying a 4-20 mA isolator. The lowest cost approach is a Two-Wire System using Output Loop Powered devices...WHITEPAPER: The Importance of Signal Isolation (Log in to view the file)Learn How to Recognize the Need for Isolation Learn how to recognize the need for isolation in this easy to understand white paper. This paper covers the basic aspects of electrical isolation, what it does for you, why you need it, and how we test for it. Common Methods Of Signal Isolation So the real... -
Specs & Data Sheets
-
Software
-
Accessories
-
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
TTBus-Kit: DIN Rail Bus Power Connector
- One kit supports multiple SP Series Splitters or DT and TT Series transmitters.
$30Select options -
TTC-SIP: Software
- Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
- Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
- Easy setup and digital calibration via USB with Windows configuration software.
- Download the configuration software only - from the Software Tab
$170Select options -
USB Isolator
- USB-powered, USB 2.0 and 1.1 compatible
- 1500V AC / 2100V DC isolation
- No drivers required
$110Select options
-
Additional information
Additional information
Weight 8 oz Dimensions 4.51 × 0.5 × 3.9 in Part Number TT336-0700: Four-wire transmitter
Configuration Agility Mobile App, Factory Calibration, USB Configuration, Windows Software Configuration
Product Series TT330 Series
Please login to submit this form.