Click to zoom
$670$800

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • Two CAN bus channels with optional isolation
  • NXP SJA1000 CAN controller with TJA1043 transceiver
[DISPLAY_ULTIMATE_PLUS]

IP560 modules provide two independent CAN bus interface channels. Each channel has a NXP SJA1000 CAN controller with a TJA1043 transceiver. The advantage of this design is that it allows reporting of bus fault conditions directly from the TJA1043 transceivers. It also has the ability to transmit, receive and perform message filtering on extended and standard messages.

Using CAN to network controllers, actuators, sensors, and transducers provides many benefits to system developers. First, the ready availability of multi-sourced components and tools can significantly reduce design time. Next, the small, light cables used by CAN help lower connection costs. Additionally, CAN has fewer connections which improves reliability.

CAN is ideal for the following applications:

  • Marine control and navigation systems
  • Elevator control systems
  • Defense vehicles
  • Production line control systems
  • Machine tools
  • Large optical telescopes
  • Medical systems
  • Paper and textile production machinery
  • Packaging machinery

Performance Specifications

CAN Bus

Configuration: Two independent CAN bus channels. NXP SJA1000 CAN controller with TJA1041 transceiver.
ISO 11898 standard: Supports the standard data and remote frame as well as the extended data and remote frame according to CAN specification 2.0 Part A and Part B.
Isolation
IP560: Non-isolated. Logic and field commons have a direct electrical connection.
IP560-i: 1kV DC isolation.
Maximum data rate: 1Mb/S.

IP Compliance (ANSI/VITA 4)r

Meets IP specifications per ANSI/VITA 4-1995 (R2002).
Data transfer cycle types supported: Input/output (IOSel*), ID read (IDSel*), Interrupt Select (INTSel*), Memory (MEMSel*).
Access times (8MHz clock):
ID PROM Read: 1 wait state (375nS cycle).
I/O Space Read: 1 wait state (375nS cycle).
I/O Space Write: 0 wait state (250nS cycle).
Interrrupt Select Read: 1 wait state (375nS cycle).
Memory Space Read: 3 wait state (750nS cycle).
Memory Space Write: 2 wait state (625nS cycle). Access times (32MHz clock):
ID PROM Read: 1 wait state (94nS cycle).
I/O Space Read: 1 wait state (94nS cycle).
I/O Space Write: 0 wait state (63nS cycle).
Interrrupt Select Read: 1 wait state (94nS cycle).
Memory Space Read: 5 wait state (250nS cycle).
Memory Space Write: 2 wait state (156nS cycle).

Environmental

Operating temperature: 0 to 70°C or -40 to 85°C (E models).
Storage temperature: -55 to 125°C.
Relative humidity: 5 to 95% non-condensing.
Power:
IP560/IP560E
+5V (±5%): 92 mA typical, 110 mA mA maximum.
+12 Volts (±5%): 0.12 mA typical, 0.2 mA maximum.
IP560-i/IP560E-i
+5V (±5%): 123 mA typical, 275 mA maximum.
MTBF: Contact the factory.

  • Two complete CAN bus interfaces
  • NXP SJA1000 CAN bus controller with high-speed TJA1043 CAN transceiver
  • 1000V isolation, channel-to-channel and channel-to-host (IP560-i models)
  • ISO 11898 compliance for Part A (11-bit) and Part B extended (29-bit) arbitration IDs
  • CAN 2.0B protocol compatibility (extended frame passive in PCA82C200 compatibility mode)
  • Data rates of up to 1Mb/s
  • Supports both 8MHz and 32MHz IP operation
  • 0 to 70°C or -40 to 85°C operating temperature range
  • TXD dominant clamping handler with diagnosis
  • RXD recessive clamping handler with diagnosis
  • TXD-to-RXD short-circuit handler with diagnosis
  • Bus line short-circuit diagnosis
  • Bus dominant clamping diagnosis
  • PCA82C200 mode (BasicCAN mode is default)
  • Extended receive buffer (64-byte FIFO)
  • 24 MHz clock frequency
  • PeliCAN mode extensions:
    • Error counters with read/write access
    • Programmable error warning limit
    • Last error code register
    • Error interrupt for each CAN-bus error
    • Arbitration lost interrupt with detailed bit position
    • Single-shot transmission (no re-transmission)
    • Listen only mode (no acknowledge, no active error flags)
    • Hot plugging support (software driven bit rate detection)
    • Acceptance filter extension (4-byte code, 4-byte mask)
    • Reception of ‘own’ messages (self reception request)
  • Undervoltage detection on VBAT
  • Listen-only mode for node diagnosis and failure containment

Manuals

IP560 User Manual (Log in to download the file)

Drawings & Diagrams

IPSW-API-LNX (Log in to download the file)
  • Compare

    502x Cable Series

    • Communication Signal Cables
    • Wide assortment of ribbon cables
    $40$705
    Select options
  • Compare

    Conformal Coating

    Moisture and humidity protection for boards via Acromag applied conformal coating using acrylic resin (Humiseal 1B31).  
    $55
    Select options
  • Compare

    CS-IP Conformal Coat

    Industry Pack conformal coat. This option should be selected to prevent high temperature and humidity issues (like blotching) when boards are conformal coated
    $80
    Select options
  • Compare

    IPSW-API: I/O Function Routines for VxWorks, Windows, Linux

    • Use with IndustryPack modules/carriers
    • Easy installation procedure
    • Help files with step-by-step instructions
    • Demonstration Program
    • Driver level support for desktop and embedded Windows level programming environments
    $385$1,035
    Select options
  • Compare

    Termination Products

    • DIN rail-mount panels
    • 50 screw terminals on 50-pin connector termination panels
    • 50 screw terminals on SCSI-2 connector termination panels
    • 68 screw terminals on SCSI-3 connector termination panels
    $170$235
    Select options
  • Compare

    Transition Modules

    • Various transition modules
    $235$1,030
    Select options

Additional information

Weight 8 oz
Dimensions 4 × 2 × 1 in
Part Number

IP560: CAN bus interface, IP560E: CAN bus interface, extended temperature range., IP560-i: isolated CAN bus interface

Product Series

Industry Pack

  • Description

    IP560 modules provide two independent CAN bus interface channels. Each channel has a NXP SJA1000 CAN controller with a TJA1043 transceiver. The advantage of this design is that it allows reporting of bus fault conditions directly from the TJA1043 transceivers. It also has the ability to transmit, receive and perform message filtering on extended and standard messages.

    Using CAN to network controllers, actuators, sensors, and transducers provides many benefits to system developers. First, the ready availability of multi-sourced components and tools can significantly reduce design time. Next, the small, light cables used by CAN help lower connection costs. Additionally, CAN has fewer connections which improves reliability.

    CAN is ideal for the following applications:

    • Marine control and navigation systems
    • Elevator control systems
    • Defense vehicles
    • Production line control systems
    • Machine tools
    • Large optical telescopes
    • Medical systems
    • Paper and textile production machinery
    • Packaging machinery

    Performance Specifications

    CAN Bus

    Configuration: Two independent CAN bus channels. NXP SJA1000 CAN controller with TJA1041 transceiver.
    ISO 11898 standard: Supports the standard data and remote frame as well as the extended data and remote frame according to CAN specification 2.0 Part A and Part B.
    Isolation
    IP560: Non-isolated. Logic and field commons have a direct electrical connection.
    IP560-i: 1kV DC isolation.
    Maximum data rate: 1Mb/S.

    IP Compliance (ANSI/VITA 4)r

    Meets IP specifications per ANSI/VITA 4-1995 (R2002).
    Data transfer cycle types supported: Input/output (IOSel*), ID read (IDSel*), Interrupt Select (INTSel*), Memory (MEMSel*).
    Access times (8MHz clock):
    ID PROM Read: 1 wait state (375nS cycle).
    I/O Space Read: 1 wait state (375nS cycle).
    I/O Space Write: 0 wait state (250nS cycle).
    Interrrupt Select Read: 1 wait state (375nS cycle).
    Memory Space Read: 3 wait state (750nS cycle).
    Memory Space Write: 2 wait state (625nS cycle). Access times (32MHz clock):
    ID PROM Read: 1 wait state (94nS cycle).
    I/O Space Read: 1 wait state (94nS cycle).
    I/O Space Write: 0 wait state (63nS cycle).
    Interrrupt Select Read: 1 wait state (94nS cycle).
    Memory Space Read: 5 wait state (250nS cycle).
    Memory Space Write: 2 wait state (156nS cycle).

    Environmental

    Operating temperature: 0 to 70°C or -40 to 85°C (E models).
    Storage temperature: -55 to 125°C.
    Relative humidity: 5 to 95% non-condensing.
    Power:
    IP560/IP560E
    +5V (±5%): 92 mA typical, 110 mA mA maximum.
    +12 Volts (±5%): 0.12 mA typical, 0.2 mA maximum.
    IP560-i/IP560E-i
    +5V (±5%): 123 mA typical, 275 mA maximum.
    MTBF: Contact the factory.

  • Features & Benefits

    • Two complete CAN bus interfaces
    • NXP SJA1000 CAN bus controller with high-speed TJA1043 CAN transceiver
    • 1000V isolation, channel-to-channel and channel-to-host (IP560-i models)
    • ISO 11898 compliance for Part A (11-bit) and Part B extended (29-bit) arbitration IDs
    • CAN 2.0B protocol compatibility (extended frame passive in PCA82C200 compatibility mode)
    • Data rates of up to 1Mb/s
    • Supports both 8MHz and 32MHz IP operation
    • 0 to 70°C or -40 to 85°C operating temperature range
    • TXD dominant clamping handler with diagnosis
    • RXD recessive clamping handler with diagnosis
    • TXD-to-RXD short-circuit handler with diagnosis
    • Bus line short-circuit diagnosis
    • Bus dominant clamping diagnosis
    • PCA82C200 mode (BasicCAN mode is default)
    • Extended receive buffer (64-byte FIFO)
    • 24 MHz clock frequency
    • PeliCAN mode extensions:
      • Error counters with read/write access
      • Programmable error warning limit
      • Last error code register
      • Error interrupt for each CAN-bus error
      • Arbitration lost interrupt with detailed bit position
      • Single-shot transmission (no re-transmission)
      • Listen only mode (no acknowledge, no active error flags)
      • Hot plugging support (software driven bit rate detection)
      • Acceptance filter extension (4-byte code, 4-byte mask)
      • Reception of ‘own’ messages (self reception request)
    • Undervoltage detection on VBAT
    • Listen-only mode for node diagnosis and failure containment
  • Specs & Data Sheets

    Manuals

    IP560 User Manual (Log in to download the file)

    Drawings & Diagrams

  • Software

    IPSW-API-LNX (Log in to download the file)
  • Accessories

    • Compare

      502x Cable Series

      • Communication Signal Cables
      • Wide assortment of ribbon cables
      $40$705
      Select options
    • Compare

      Conformal Coating

      Moisture and humidity protection for boards via Acromag applied conformal coating using acrylic resin (Humiseal 1B31).  
      $55
      Select options
    • Compare

      CS-IP Conformal Coat

      Industry Pack conformal coat. This option should be selected to prevent high temperature and humidity issues (like blotching) when boards are conformal coated
      $80
      Select options
    • Compare

      IPSW-API: I/O Function Routines for VxWorks, Windows, Linux

      • Use with IndustryPack modules/carriers
      • Easy installation procedure
      • Help files with step-by-step instructions
      • Demonstration Program
      • Driver level support for desktop and embedded Windows level programming environments
      $385$1,035
      Select options
    • Compare

      Termination Products

      • DIN rail-mount panels
      • 50 screw terminals on 50-pin connector termination panels
      • 50 screw terminals on SCSI-2 connector termination panels
      • 68 screw terminals on SCSI-3 connector termination panels
      $170$235
      Select options
    • Compare

      Transition Modules

      • Various transition modules
      $235$1,030
      Select options
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 4 × 2 × 1 in
    Part Number

    IP560: CAN bus interface, IP560E: CAN bus interface, extended temperature range., IP560-i: isolated CAN bus interface

    Product Series

    Industry Pack