Product short description:
  • 32 port-isolated output channels (bipolar solid state relays)
  • ±60V AC/DC output
  • High/low-side switch configuration

IP445A modules provide 32 isolated solid-state relay outputs to safely control discrete devices.

RSS
FACEBOOK
FACEBOOK
TWITTER
Visit Us
LINKEDIN

A major IP445A advantage is its flexibility. The module supports wide range bipolar (AC or DC) voltage switching. Each port can be configured for high or low-side switches. The outputs are TTL-compatible when configured as low-side switches using on-board socketed pull-up resistors.

Isolation protects your computer system from noise, transient signals, and field wiring faults. Outputs are grouped into four 8-channel ports. Ports are isolated via solid-state relays from the logic and from each other.

Readback buffers simplify output status monitoring. And for easy closed-loop monitoring of critical control signals, use the IP445A with an IP440A input module.

Specifications

Digital Outputs: Output channel configuration: 32 isolated solid-state relays support AC or DC (high/low-side switching) operation.

Isolation: Logic and field connections are optically isolated by solid-state relays. Individual ports are also isolated from each other. Output lines of an individual port share a common connection and are not isolated from each other. IP Logic and field lines are isolated from each other for voltages up to 250V AC or 354V DC on a continuous basis (unit will withstand a 1000V AC  dielectric strength test for one minute without breakdown).

Voltage range: 0 to ±60V DC or peak AC.

Output ON current range: 140mA maximum continuous (up to 1A total per port).

Turn on time: IP445A 1mS typical, 2mS maximum. IP445AE 1mS typical, 2.5mS maximum*.

Turn off time: IP445A 1mS typical, 2mS maximum. IP445AE 1mS typical, 2.5mS maximum*.

*maximum values are measured at 85°C

Output pull-up resistors: 4.7K ohms, socketed.

IP Compliance (ANSI/VITA 4)

Meets IP specifications per ANSI/VITA 4-1995.

IP data transfer cycle types supported: Input/output (IOSel*), ID read (IDSel*).

Access times (8MHz clock): 0 wait states (250ns cycle).

Updates: Requires four 8-bit writes to update all channels.

Environmental

Operating temperature: 0 to 70°C (IP445A) or -40 to 85°C (IP445AE model).

Storage temperature: -40 to 150°C (all models).

Relative humidity: 5 to 95% non-condensing.

MTBF: 713,455 hrs at 25°C, MIL-HDBK-217F,Notice 2.

Power: +5V (±5%) all outputs on: 200mA maximum. ±5V (±5%) all outputs off: 8mA maximum.

The IP445A is a drop-in replacement for the IP445, please see the known differences document below for more information.

Known Differences Between the IP445 and the IP445A Statement

  • Unique ground reference points for each port permits AC and DC switching on one module.
  • Pin are compatible with IP440A input module for loopback monitoring.
  • 32 bipolar solid state relays
  • High/low-side switch configuration
  • Port-isolated output channels
  • ±60V AC/DC voltage range
  • High speed processing (0 wait states)
  • TTL-compatible
  • Failsafe power-up and system reset
  • Output readback function
  • Socketed pull-up resistors for low-side switching applications
  • Current-limited solid-state relays
  • 0 to 70°C (IP445) or -40 to 85°C (IP445E model)

Manuals

IP445A User Manual (Log in to download the file)

Known Difference Between IP445 and IP445A (Log in to download the file)

Additional information

Weight N/A
Dimensions N/A
Part Number

IP445A: 32 port isolated output channels., IP445AE: 32 port isolated output channels, extended temp. range.

  • Description

    A major IP445A advantage is its flexibility. The module supports wide range bipolar (AC or DC) voltage switching. Each port can be configured for high or low-side switches. The outputs are TTL-compatible when configured as low-side switches using on-board socketed pull-up resistors.

    Isolation protects your computer system from noise, transient signals, and field wiring faults. Outputs are grouped into four 8-channel ports. Ports are isolated via solid-state relays from the logic and from each other.

    Readback buffers simplify output status monitoring. And for easy closed-loop monitoring of critical control signals, use the IP445A with an IP440A input module.

    Specifications

    Digital Outputs: Output channel configuration: 32 isolated solid-state relays support AC or DC (high/low-side switching) operation.

    Isolation: Logic and field connections are optically isolated by solid-state relays. Individual ports are also isolated from each other. Output lines of an individual port share a common connection and are not isolated from each other. IP Logic and field lines are isolated from each other for voltages up to 250V AC or 354V DC on a continuous basis (unit will withstand a 1000V AC  dielectric strength test for one minute without breakdown).

    Voltage range: 0 to ±60V DC or peak AC.

    Output ON current range: 140mA maximum continuous (up to 1A total per port).

    Turn on time: IP445A 1mS typical, 2mS maximum. IP445AE 1mS typical, 2.5mS maximum*.

    Turn off time: IP445A 1mS typical, 2mS maximum. IP445AE 1mS typical, 2.5mS maximum*.

    *maximum values are measured at 85°C

    Output pull-up resistors: 4.7K ohms, socketed.

    IP Compliance (ANSI/VITA 4)

    Meets IP specifications per ANSI/VITA 4-1995.

    IP data transfer cycle types supported: Input/output (IOSel*), ID read (IDSel*).

    Access times (8MHz clock): 0 wait states (250ns cycle).

    Updates: Requires four 8-bit writes to update all channels.

    Environmental

    Operating temperature: 0 to 70°C (IP445A) or -40 to 85°C (IP445AE model).

    Storage temperature: -40 to 150°C (all models).

    Relative humidity: 5 to 95% non-condensing.

    MTBF: 713,455 hrs at 25°C, MIL-HDBK-217F,Notice 2.

    Power: +5V (±5%) all outputs on: 200mA maximum. ±5V (±5%) all outputs off: 8mA maximum.

    The IP445A is a drop-in replacement for the IP445, please see the known differences document below for more information.

    Known Differences Between the IP445 and the IP445A Statement

  • Features & Benefits

    • Unique ground reference points for each port permits AC and DC switching on one module.
    • Pin are compatible with IP440A input module for loopback monitoring.
    • 32 bipolar solid state relays
    • High/low-side switch configuration
    • Port-isolated output channels
    • ±60V AC/DC voltage range
    • High speed processing (0 wait states)
    • TTL-compatible
    • Failsafe power-up and system reset
    • Output readback function
    • Socketed pull-up resistors for low-side switching applications
    • Current-limited solid-state relays
    • 0 to 70°C (IP445) or -40 to 85°C (IP445E model)
  • Specs & Data Sheets

    Manuals

    IP445A User Manual (Log in to download the file)

    Known Difference Between IP445 and IP445A (Log in to download the file)

  • Additional information

    Additional information

    Weight N/A
    Dimensions N/A
    Part Number

    IP445A: 32 port isolated output channels., IP445AE: 32 port isolated output channels, extended temp. range.