DT330 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT333 model is a four-wire dual transmitter that isolates and converts millivolt or thermocouple sensor inputs to proportional control signals. Each channel supports DC current or voltage output. An optional DIN rail bus can deliver primary or redundant power to multiple units. High-voltage isolation separates inputs, outputs, and power from each other. Isolation protects from surges, reduces noise, and eliminates ground loop errors. Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices. Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

Performance Specifications

IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a DT330 Series transmitter.

USB Interface

USB Connection Type: USB Mini-B type socket, 5-pin Data Rate: 12Mbps. USB v1.1 and 2.0 compatible Maximum cable length: 5.0 meters Transient voltage suppression on power and data lines. USB Driver: Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system.

Input (two channels)

Default Configuration/Calibration Input: TC J, -210 to 760°C, medium filter Output: 4 to 20mA, upscale break detect Input Ranges Input                         Range                                     Accuracy TC J         -210 to 760°C (-346 to 1400°F)              ±0.5°C TC K        -200 to 1372°C (-328 to 2502°F)            ±0.5°C TC T        -260 to 400°C (-436 to 752°F)                 ±0.5°C TC R          -50 to 1768°C (-58 to 3214°F)               ±1.0°C TC S           -50 to 1768°C (-58 to 3214°F)              ±1.0°C TC E         -200 to 1000°C (-328 to 1832°F)           ±0.5°C TC B          260 to 1820°C (500 to 3308°F)             ±1.0°C TC N        -230 to -170°C (-382 to -274°F)              ±1.0°C TC N        -230 to -1300°C (-274 to 2372°F            ±0.5°C mV           -100 to 100mV                                             ±0.05% Thermocouple Reference (Cold Junction Compensation): ±0.2°C typical, ±0.5°C maximum at 25°C Ambient Temperature Effect: Better than ±80ppm/°C (±0.008%/°C) Scaling Adjust: Full range Lead Break (Sensor Burnout) Detection: Upscale/downscale full range Input Impedance: 15M ohms Input Over-Voltage Protection: Bipolar Transient Voltage Suppression (TVS) and diode clamping. Input Filter: RC filter plus variable digital filter (none, low, medium, high) Noise Rejection: Common Mode: 96dB no filter (134dB high filter) Normal Mode: 0.12dB no filter, 60Hz (>80dB med/high filter)

Output (two channels)

D/A Converters (DAC): Two 16-bit D/A converters Output Ranges: ±10V (±11V maximum) ±5V (±5.5V maximum) 0 to 10V (11V maximum) 0 to 5V (5.5V maximum) 0 to 20mA (24mA maximum) 4 to 20mA (24mA maximum) Output Accuracy: ±0.05%, typical. ±0.1%, maximum Output Load: Voltage output: 1K ohms minimum. Current output: 0-550 ohms Output Compliance: 11V, typical Output Response Time (for step input change) Time to reach 98% of output value (typical) No filtering               13 milliseconds Low filter                   38 milliseconds Medium filter        122 milliseconds High filter             1158 milliseconds Output Ripple: Less than ±0.1% of output span

Environmental

Operating temperature Operation: -40 to 70°C (-40° to 158°F) Storage: -40 to 85°C (-40 to 185°F) Relative humidity: 5 to 95% non-condensing Power Requirement: 6-32V DC SELV, 1.6W max Isolation: 1500V AC peak. 250V AC (354V DC) continuous isolation between inputs, outputs, and power (5-way) Shock and Vibration Immunity: Vibration: 4g, per IEC 60068-2-6 Shock: 25g, per IEC 60068-2-27 Approvals (pending) CE compliant. Designed for UL/cUL Class I Division 2 Groups ABCD, ATEX / IECEx Zone 2. II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C Electromagnetic Compatibility (EMC) Compliance Radiated Emissions: BS EN 61000-6-4, CISPR 16 RFI: BS EN 61000-6-2, IEC 61000-4-3 Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6 ESD: BS EN 61000-6-2, IEC 61000-4-2 EFT: BS EN 61000-6-2, IEC 61000-4-4 Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5

Physical

General: General-purpose enclosure designed for mounting on 35mm “T-type” DIN rail Case Material: Self-extinguishing polyamide, UL94 V-0 rated I/O Connectors: Removable plug-in terminal blocks rated for 12A/250V; AWG #26-12, stranded or solid copper wire Dimensions: 17.5 x 114.5 x 99.0 mm (0.7 x 4.51 x 3.90 inches) Unit weight: 0.16 kg (0.35 pounds) Shipping Weight: 0.22 kg (0.5 pounds) packed

Showing all 5 results

  • Compare

    DT333: Thermocouple/milliVolt Input Four-wire Dual Transmitter

    • Dual channels
    • Universal thermocouple, mV inputs
    • 6-32V DC local/bus power
    $370
    Select options
  • Compare

    DT336: Current/Voltage Input Four-wire Dual Transmitter

    • Dual channels
    • ±20mA, ±500mV inputs
    • 0-20mA, ±10V outputs
    • 6-32V DC local/bus power
    $325
    Select options
  • Compare

    DT335: RTD/Resistance Input Four-wire Dual Transmitter

    • Dual channels
    • RTD (Pt, Ni, Cu) or 0-4500 ohm input
    • 0-20mA, ±10V outputs
    • 6-32V DC local/bus power
    $340
    Select options
  • Compare

    DT337: Medium DC Voltage Input Four-wire Dual Transmitter

    • Dual channels
    • ±1V, ±10V inputs
    • 0-20mA, ±10V outputs
    • 6-32V DC local/bus power
    $340
    Select options
  • Compare

    DT338: High DC Voltage Input Four-wire Dual Transmitter

    • Dual channels
    • ±15V, ±150V inputs
    • 0-20mA, ±10V outputs
    • 6-32V DC local/bus power
    $355