Description

These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function. Each unit offers a selection of input and output ranges, as well as several signal conditioning options. This flexibility enables a single IntelliPack to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions. Setup is very easy. IntelliPack modules are quickly configured with the user-friendly Windows software program. Field adjustments are simple with the module’s front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.

Performance

General Input

Analog to Digital (A/D) Converter: 16-bit Σ-Δ A/D converter Resolution: ±0.005% of span or 0.1°C Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater. Noise Rejection: Normal Mode: Better than 40dB @ 60Hz Common Mode: Better than 130dB @ 60Hz Input Response Time (for input step change): Less than 200mS typical to 98% of final output value Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)

Thermocouple Input

Thermocouple Input Ranges Thermocouple type user configured. Signal linearization, cold-junction compensation, and open circuit or lead break detection are included. TC             °C Range (°F Range)                     Accuracy J        -210 to  760°C (-346 to 1400°F)              ±0.5°C K       -200 to 1372°C (-328 to 2502°F)             ±0.5°C T       -260 to  400°C (-436 to 752°F)                 ±0.5°C R         -50 to 1768°C (-58 to 3214°F)                ±1.0°C S         -50 to 1768°C (-58 to 3214°F)                ±1.0°C E       -200 to 1000°C (-328 to 1832°F)             ±0.5°C B        260 to 1820°C (500 to 3308°F)               ±1.0°C N      -230 to 1300°C (-382 to 2372°F)             ±1.0°C Thermocouple Break Detection: TC sensor failure can be configured for either upscale or downscale

RTD Input

RTD Input Ranges:100 ohm Platinum, 120 ohm Nickel, or 10 ohm Copper; user-configured RTD                °C Range (°F Range)                       Accuracy Pt1            -200 to 850°C (-328 to 1562°F)              ±0.25°C Pt2            -200 to 850°C (-328 to 1562°F)              ±0.25°C Ni                 -80 to 320°C (-112 to 608°F)                 ±0.25°C Cu             -200 to 260°C (-328 to 500°F)                 ±1.00°C Alpha: Pt1 (a = 1.3850), Pt2 (a = 1.3911), Ni (a = 1.6720), Cu (a = 1.4272) 2, 3, or 4-wire configurations supported. Module provides sensor excitation, linearization, lead-wire compensation, and sensor break detection. RTD Excitation Current: 1mA DC typical, all types RTD Lead-Wire Compensation: 25 ohms per lead RTD Break Detection: RTD sensor failure can be configured for either upscale or downscale.

milliVolt Input

DC milliVolt/Voltage Input Ranges:  ±1.0V           ±125mV          ±31.25mV ±500mV     ±62.5mV        ±15.625mV       ±250mV milliVolt Accuracy: better than ±0.05% of input span

Resistance Input

Resistance Input Range: 0 to 500 ohms Resistance Accuracy: ±0.05 ohms

Output (DC V/mA)

D/A Converter: 16-bit Σ-Δ Current Output: 0-1mA, 0-20mA, 4-20mA Compliance: 10V minimum (500 ohm load) Accuracy: 0.025% of span Voltage Output: Ranges: 0-5V, 0-10V Compliance: 10mA maximum with short circuit protection. 1 ohm output impedance Accuracy: 0.025% of span Accuracy (overall input to output): 0.075% of span

Output (Relay)

Relay: One SPDT electro-mechanical relay Relay Ratings (CSA ratings): 25V DC @ 5A 120/240V AC @ 5A Relay Time Delay: Adjustable alarm delay of up to 25 seconds Contact Material: Silver-cadmium oxide (AgCdO) Expected Mechanical Life: 20 million operations

Environmental

Ambient Temperature: Operating: -25 to 70°C (-13 to 158°F) Storage: -40 to 85°C (-40 to 185°F) Relative Humidity: 5 to 95% Power Requirements: 10 to 36V DC. 75mA @ 24V. 120mA @ 15V Isolation (optical): 4-way (input/output/relay/power) 1500V AC for 60 seconds or 250V AC continuous Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1 Electromagnetic Field Immunity (EMI): Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors. Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1 Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1 Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1 Radiated Emissions: EN50081-1 for Class B equipment Approvals: UL, cUL listed (USA, Canada) UL3121 - general product safety

Configuration

Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit. Field Configuration: Output, zero/full-scale, relay setpoint and deadband are configurable via push-buttons and a standard calibrator. LED Indicators: LEDs indicate power, status, calibration, and alarm.

Physical

Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure. Connectors (Removable terminal blocks): Wire Range: AWG #14-22 (AWG #12 stranded only) Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board Dimensions 1.05W x 4.68H x 4.35D inches 26.7W x 118.9H x 110.5D millimeters Shipping Weight: 1 pound (0.45 Kg) packed

Showing all 3 results

  • Compare

    801T: Intelligent Temperature Transmitter; Universal Input (TC/RTD/mV/Resistance)

    • 0 to 20mA DC, 0 to 10V DC output
    • Mechanical relay (25V @ 5A) alarm
    • 10-36V DC power
    • Software configured
    • Performs linearization, square root extraction, and optional limit alarm functions
    $355$495
    Read more
  • Compare

    811T: Intelligent Transmitter, DC Voltage/Current Input

    • ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
    • 0 to 20mA DC, 0 to 10V DC output
    • Mechanical relay alarm (25V @ 5A)
    • 10-36V DC power
    • Software configured, performs linearization, square root extraction, and optional limit alarm functions
    $335$495
    Select options
  • Compare

    841T: Intelligent Transmitter; DC Frequency/Pulse Input

    • 0 to 50KHz, 0 to 65535 pulses input
    • 0 to 20mA DC, 0 to 10V DC output
    • Mechanical alarm relay (25V @ 5A)
    • 10-36V DC power
    • Software configured; pulse counter; signal averaging; optional limit alarm functions
    $355$495