Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing 1–16 of 21 results

  • Compare

    VPM3000 Series: Universal Transmitter / Alarm with Display

    • Big, bright display
    • 4-20mA, ±10V, thermocouple, or RTD input
    • 4-20mA, Modbus serial, or alarm relay output options
    Acromag VPM3000 Vertu™ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications. Learn more about the VPM3000 by watching this short video.
    Select options
  • Compare

    20RM-16-DIN: 19” rack-mount kit with DIN rail

    • 19" rack-mount kit with DIN rail
    Select options
  • Compare

    350T NEMA Enclosure

    Mounting Accessories NEMA-4 and MEMA-12 Enclosures
    Read more
  • Compare

    5034-186: Configuration Software CD-ROM

    • Configuration software CD
    Acromag’s configuration software is the key to the I/O modules’ easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
    Select options
  • Compare

    900C-SIP: Configuration Software Interface Package

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RS485 Adapter
    • Interface Cable
     
    Select options
  • Compare

    913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms

    • 4 input channels
    • 0 to 20mA DC (0 to 20A AC with AC sensor) or ±10V DC input range
    • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus RTU high-speed RS-485
    This signal conditioner is a four-channel analog input module with four discrete outputs. It provides isolation between input, output, power, and network circuits.
    Select options
  • Compare

    917MB, 918MB: DC Current/Voltage Modbus-RTU Output Modules with Discrete Outputs

    • 4 analog output channels
    • 0 to 20mA or 0 to 10V DC output range
    • 4 discrete output channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus RTU high-speed RS-485
    These modules drive four analog output channels and also feature four discrete outputs for on/off control. Isolation separates the output, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus RTU protocol.
    Select options
  • Compare

    924MB: Thermocouple/milliVolt Modbus-RTU Input Module with Limit Alarms

    • 4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt (±100mV DC) input
    • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a four-channel analog input module with four discrete outputs. It filters and linearizes thermocouple inputs while providing isolation between input, output, power, and network circuits. Cold junction compensation and upscale/downscale sensor break detection are standard.  
    Select options
  • Compare

    932MB, 934MB: RTD/Resistance Modbus-RTU Input Modules with Limit Alarms or Discrete Outputs

    • 2 or 4 input channels, RTD (100 ohm Pt, 120 ohm Ni, 10 ohm Cu) or resistance (0 to 500 ohms) input
    • Solid-state relays discrete output, Form A, SPST-NO
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a dual or quad-channel analog input module with one discrete/relay output per input channel and a Modbus interface. It filters and linearizes RTD or resistance inputs while providing isolation between input, output, power, and network circuits.
    Select options
  • Compare

    942MB: Frequency/Pulse Counter Modbus-RTU Input Modules with Periodic or Pulse Waveform Input

    • 2 input channels, 0 to 50KHz in 3 selectable ranges: Amplitudes up to 140V AC peak, Amplitudes up to 200V peak, Pulse counter range of 0 to 65535
    • Solid-state discrete output relays (1A DC loads), 0 to 48V DC
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a two-channel analog input module with discrete outputs and Modbus communication. It conditions periodic or pulse waveform inputs and provides solid-state relays for limit alarms or ON/OFF control.
    Select options
  • Compare

    ACC1014: Flat Pack Mounting Kit

    • Surface mount for 250T, 260A and 270i series
    • Snaptrack mount 250T, 260A and 270i series
    Select options
  • Compare

    AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O

    • Modbus/TCP or Modbus/RTU
    • These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
    • Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
    Select options
  • Compare

    Digital Display Panel Meter Accessories

    • Plastic enclosure
    • Pipe-mount kit
    • Cables
    • Adapters
    Select from a variety of of panel meter accessories.  
    Select options
  • Compare

    DIN Rail: Type T

    • DIN Rail Strip, Type T
    Select options
  • Compare

    EtherStax Mounting Kits

    • EtherStax mounting accessories
    Select options
  • Compare

    ST130 Mounting Accessories

    • Simplifies mounting of ST130 Series transmitters
    • Ideal for mounting in the field or in a control room
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms