Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing all 12 results

  • Compare

    VPM3000 Series: Universal Transmitter / Alarm with Display

    • Big, bright display
    • 4-20mA, ±10V, thermocouple, or RTD input
    • 4-20mA, Modbus serial, or alarm relay output options
    Acromag VPM3000 Vertuâ„¢ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications. Learn more about the VPM3000 by watching this short video.
    Select options
  • Compare

    5034-186: Configuration Software CD-ROM

    • Configuration software CD
    Acromag’s configuration software is the key to the I/O modules’ easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
    Select options
  • Compare

    801A Universal TC/RTD/mV Input Intelligent Alarm

    • Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), resistance (0 to 500 ohms) input
    • Single or dual mechanical relay alarm outputs
    • 10-36V DC power
    • Software configured
    • Multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection)
    • On/off controller capability
    IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.
    Select options
  • Compare

    801T: Universal Input Intelligent Temperature Transmitter

    • Thermocouple, RTD, milliVolt, and Resistance Input
    • 0 to 20mA DC, 0 to 10V DC output
    • Limit Alarm
    • 10-36V DC power
    • Software configured
    • Performs linearization, square root extraction, and optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    822A Dual Thermocouple/mV Input Intelligent Alarm

    • 2 input channels, thermocouple (types J, K, T, R, S, E, B, N), or millivolt (±100mV DC) input
    • Dual mechanical relays output
    • 10-36V DC power
    • Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
    IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.
    Select options
  • Compare

    900C-SIP: Configuration Software Interface Package

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RS485 Adapter
    • Interface Cable
     
    Select options
  • Compare

    901MB, 902MB, 903MB: Multi-Channel Modbus-RTU Discrete I/O Modules

    • Active-Low Inputs, Sinking Outputs (Low-Side Switching)
    • 12 input and/or 12 output channels
    • 0 to 35V DC I/O range
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    These modules provide twelve discrete input and/or output channels. Isolation separates the I/O, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus-RTU protocol.    
    Select options
  • Compare

    904MB, 905MB, 906MB: Multi-Channel Discrete I/O Modules

    • Active-High Inputs, Sourcing Outputs (High-Side Switching)
    • 12 input and/or 12 output channels
    • 0 to 35V DC I/O range
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    These modules provide twelve discrete input and/or output channels. Isolation separates the I/O, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus RTU protocol.
    Select options
  • Compare

    924MB: Thermocouple/milliVolt Modbus-RTU Input Module with Limit Alarms

    • 4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt (±100mV DC) input
    • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a four-channel analog input module with four discrete outputs. It filters and linearizes thermocouple inputs while providing isolation between input, output, power, and network circuits. Cold junction compensation and upscale/downscale sensor break detection are standard.  
    Select options
  • Compare

    AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O

    • Modbus/TCP or Modbus/RTU
    • These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
    • Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
    Select options
  • Compare

    APM765 Series: Universal Input with Alarm Panel Meter

    • Universal input
    • Isolated 4-20mA and Modbus output options
    • Push-button or PC programmable,
    • 85-265V AC or 90-265V DC power, optional 12-24V AC or 12-36V DC power
    The APM765 displays data collected from process current, DC voltage and temperature inputs. Several output options convert the display into a transmitter with proportional 4-20mA output or a serial communication interface.
    Select options
  • Compare

    XT-SIP: Software Interface Package

    • Software Interface Package for BusWorks XT Series Ethernet I/O modules.
    • Easy setup and digital calibration via USB with Windows configuration software
    • Download software only from the Software Tab below
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms