Acromag remote I/O modules feature signal conditioners and network I/O for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
Showing all 16 results
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
801A Universal TC/RTD/mV Input Intelligent Alarm
- Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), resistance (0 to 500 ohms) input
- Single or dual mechanical relay alarm outputs
- 10-36V DC power
- Software configured
- Multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection)
- On/off controller capability
-
801T: Universal Input Intelligent Temperature Transmitter
- Thermocouple, RTD, milliVolt, and Resistance Input
- 0 to 20mA DC, 0 to 10V DC output
- Limit Alarm
- 10-36V DC power
- Software configured
- Performs linearization, square root extraction, and optional limit alarm functions
-
822A Dual Thermocouple/mV Input Intelligent Alarm
- 2 input channels, thermocouple (types J, K, T, R, S, E, B, N), or millivolt (±100mV DC) input
- Dual mechanical relays output
- 10-36V DC power
- Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
-
924MB: Thermocouple/milliVolt Modbus-RTU Input Module with Limit Alarms
- 4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt (±100mV DC) input
- 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
ACC1014: Flat Pack Mounting Kit
- Surface mount for 250T, 260A and 270i series
- Snaptrack mount 250T, 260A and 270i series
-
ST130 Mounting Accessories
- Simplifies mounting of ST130 Series transmitters
- Ideal for mounting in the field or in a control room
-
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
-
TTC-SIP: Software
- Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
- Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
- Easy setup and digital calibration via USB with Windows configuration software.
- Download the configuration software only - from the Software Tab
-
TTBus-Kit: DIN Rail Bus Power Connector
- One kit supports multiple TT330 series transmitters.
- For multiple DT330/351 or SP330 transmitters, one TTBUS-KIT is required for each transmitter to be DC Power wired via the bus rail power connections.
Signal Conditioning Selection Guide Videos
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.