Acromag remote I/O modules feature signal conditioners and network I/O for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
Showing 1–16 of 19 results
-
DT235: RTD / Resistance Input Two-Wire Dual Transmitter
- Dual channels
- RTD (Pt, Ni, Cu), 0-4500 ohm inputs
- 4-20mA output (sink/source)
- 7-32V DC loop power
Click here to watch a short video highlighting the features of the DT235.
-
DT335: RTD / Resistance Input Four-wire Dual Transmitter
- Dual channels
- RTD (Pt, Ni, Cu) or 0-4500 ohm input
- 0-20mA, ±10V outputs
- 6-32V DC local/bus power
-
NT2610: Ethernet Thermocouple milliVolt Input Modules with Discrete I/O
Contact Factory for Availability- 8 thermocouple / mV inputs
- 2 discrete I/O
- Ethernet I/O plus Expansion I/O
- Multi-protocol support
-
NT2620: Ethernet RTD/Resistance Input Modules with Discrete I/O
Contact Factory for Availability- 4 RTD/resistance inputs
- 2 discrete I/O
- Ethernet I/O plus Expansion I/O
- Multi-protocol support
-
TT231: RTD / Resistance Input Two-Wire Transmitter
- 100 ohm Pt RTD or 0-900 ohm input
- 4-20mA output (sink/source)
- 12-32V DC loop/local power
- USB configuration
-
VPM3000 Series: Universal Transmitter / Alarm with Display
- Big, bright display
- 4-20mA, ±10V, thermocouple, or RTD input
- 4-20mA, Modbus serial, or alarm relay output options
-
657T, 658T: Single or Dual Channel, RTD Input, Loop-powered Transmitter
- 100 ohm Pt, 120 ohm Ni, 10 ohm Cu (selectable type) input
- 4 to 20mA DC output
- 12-50V DC from output loop power
- DIP-switch configuration, push-button calibration
-
801A Universal TC/RTD/mV Input Intelligent Alarm
- Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), resistance (0 to 500 ohms) input
- Single or dual mechanical relay alarm outputs
- 10-36V DC power
- Software configured
- Multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection)
- On/off controller capability
-
801T: Universal Input Intelligent Temperature Transmitter
- Thermocouple, RTD, milliVolt, and Resistance Input
- 0 to 20mA DC, 0 to 10V DC output
- Limit Alarm
- 10-36V DC power
- Software configured
- Performs linearization, square root extraction, and optional limit alarm functions
-
822A Dual Thermocouple/mV Input Intelligent Alarm
- 2 input channels, thermocouple (types J, K, T, R, S, E, B, N), or millivolt (±100mV DC) input
- Dual mechanical relays output
- 10-36V DC power
- Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
-
841T: DC Frequency/Pulse Input Intelligent Transmitter
- 0 to 50KHz, 0 to 65535 pulses input
- 0 to 20mA DC, 0 to 10V DC output
- Mechanical alarm relay (25V @ 5A)
- 10-36V DC power
- Software configured; pulse counter; signal averaging; optional limit alarm functions
-
924MB: Thermocouple/milliVolt Modbus-RTU Input Module with Limit Alarms
- 4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt (±100mV DC) input
- 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
942MB: Frequency/Pulse Counter Modbus-RTU Input Modules with Periodic or Pulse Waveform Input
- 2 input channels, 0 to 50KHz in 3 selectable ranges: Amplitudes up to 140V AC peak, Amplitudes up to 200V peak, Pulse counter range of 0 to 65535
- Solid-state discrete output relays (1A DC loads), 0 to 48V DC
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
965EN: Ethernet Thermocouple milliVolt Input Modules
- 4 or 6-channel thermocouple/milliVolt input
- Ethernet/IP, Modbus TCP/IP
- i2o peer-to-peer available for Modbus TCP/IP 6-channel only
-
966EN: Ethernet RTD Resistance Input Modules
- 4 or 6-channel RTD/resistance input
- Ethernet/IP, Modbus TCP/IP
- i2o peer-to-peer available for Modbus TCP/IP 6-channel only
-
ST131: Transmitter, RTD Input, Loop-Powered
- 100 ohm Pt RTD or 0-900 ohm input
- 4 to 20mA DC output
- 9-32V DC from output loop power
- USB-configured
Signal Conditioning Selection Guide Videos
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.