Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing all 8 results

  • Compare

    NT2610: Ethernet Thermocouple milliVolt Input Modules with Discrete I/O

    • 8 thermocouple / mV inputs
    • 2 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2610 Ethernet thermocouple modules and Ethernet millivolt modules offer 8 TC / mV inputs and 2 bidirectional discrete digital I/O channels. Each input can support a variety of sensor types. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2620: Ethernet RTD/Resistance Input Modules with Discrete I/O

    • 4 RTD/resistance inputs
    • 2 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2620 modules offer 4 RTD/resistance inputs and 2 bidirectional discrete digital I/O channels. Each input can support RTD or resistance sensor types. NTE Ethernet models provide a network interface to monitor temperature levels. Click here to watch a short video highlighting the benefits of the NT1620.
    Select options
  • Compare

    901MB, 902MB, 903MB: Multi-Channel Modbus-RTU Discrete I/O Modules

    • Active-Low Inputs, Sinking Outputs (Low-Side Switching)
    • 12 input and/or 12 output channels
    • 0 to 35V DC I/O range
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    These modules provide twelve discrete input and/or output channels. Isolation separates the I/O, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus-RTU protocol.    
    Select options
  • Compare

    904MB, 905MB, 906MB: Multi-Channel Discrete I/O Modules

    • Active-High Inputs, Sourcing Outputs (High-Side Switching)
    • 12 input and/or 12 output channels
    • 0 to 35V DC I/O range
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    These modules provide twelve discrete input and/or output channels. Isolation separates the I/O, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus RTU protocol.
    Select options
  • Compare

    951EN, 952EN: Ethernet Analog and Discrete I/O Modules

    • 4 analog inputs
    • 2 analog output
    • 6 discrete I/O channels
    • Ethernet/IP, Modbus TCP/IP
    • i2o peer-to-peer available for Modbus TCP/IP only
    These modules provide an isolated Ethernet network interface for analog and discrete I/O signals. Multi-range analog inputs and outputs support a wide variety of industrial devices. High-resolution, low noise, A/D and D/A converters deliver high accuracy and reliability.
    Select options
  • Compare

    965EN: Ethernet Thermocouple milliVolt Input Modules

    • 4 or 6-channel thermocouple/milliVolt input
    • Ethernet/IP, Modbus TCP/IP
    • i2o peer-to-peer available for Modbus TCP/IP 6-channel only
    These modules provide an isolated Ethernet network interface for up to six input channels. Differential inputs eliminate ground noise and each terminal block includes a cold junction compensation (CJC) sensor for more precise temperature measurements. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.    
    Select options
  • Compare

    966EN: Ethernet RTD Resistance Input Modules

    • 4 or 6-channel RTD/resistance input
    • Ethernet/IP, Modbus TCP/IP
    • i2o peer-to-peer available for Modbus TCP/IP 6-channel only
    These modules provide an isolated Ethernet network interface for up to six input channels. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability. Three-way isolation further improves the system performance.  
    Select options
  • Compare

    NT2510 and NT2530: Ethernet Multi-Function I/O Modules

    • 4 analog inputs
    • 2 analog outputs
    • 4 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2510 modules offer 4 current inputs, 2 current outputs, and 4 discrete I/O channels. NT2530 models have voltage input. NTE Ethernet models provide a network interface to monitor and control I/O signals. Appending NTX expansion models can interface up to 24 analog and 16 discrete I/O on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms