Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing 1–16 of 40 results

  • Compare

    DT233: Thermocouple / milliVolt Input Two-Wire Dual Transmitter

    • Dual channels
    • Universal thermocouple, mV input
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop/local
    The DT233 model is a dual two-wire transmitter that isolates and converts millivolt or thermocouple sensor inputs to proportional 4-20mA control signals. Power is received from the output loop current.

    Click here to watch a short video highlighting the features of the DT233.

     
    Select options
  • Compare

    DT333: Thermocouple / milliVolt Input Four-Wire Dual Transmitter

    • Dual channels
    • Universal thermocouple, mV inputs
    • Isolated current or voltage outputs
    • 6-32V DC local/bus power
    The DT333 model is a four-wire dual transmitter that isolates and converts millivolt or thermocouple sensor inputs to proportional control signals. Each channel supports DC current or voltage output. Click here to watch a short video highlighting the features of the DT333
    Select options
  • Compare

    TT233: Thermocouple / milliVolt Input Two-Wire Transmitter

    • Universal TC type J, K, T, R, S, E, B, N or ±100mV input
    • 4-20mA ouput (sink/source)
    • 12-32 V DC loop/local power
    The TT233 model is a space-saving two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.        
    Select options
  • Compare

    TT333: Thermocouple / milliVolt Input Four-wire Transmitter

    • Universal thermocouple / millivolt input
    • Universal current / voltage output
    • 12-32V DC local / bus power
    The TT333 model is a space-saving four-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional control signal. DC current and voltage output are both supported on a single model. Click here to watch a short video highlighting the TT330 Series.    
    Select options
  • Compare

    TT336: Current/milliVolt Input, DC Power Transmitter

    • Multi-range ±20mA or ±500mV input
    • Universal current/voltage output
    • 12-32V DC power
    DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring. Click here to watch a short video highlighting the TT330 Series.  
    Select options
  • Compare

    DT336: Current / milliVolt Input Four-Wire Dual Transmitter

    • Dual channels
    • ±20mA, ±500mV inputs
    • 0-20mA, ±10V outputs
    • 6-32V DC local/bus power
    The DT336 model is a four-wire dual transmitter that isolates and converts DC current or low voltage inputs to proportional control signals. Each channel supports DC current or voltage output.

    Click here to watch a short video highlighting the features of the DT336.

    Select options
  • Compare

    NT2210: Ethernet Analog I/O Modules with 8 Differential Current Inputs, 2 Discrete I/O

    • 8 differential current inputs
    • 2 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2210 modules offer 8 current inputs and 2 limit alarms. Each input has true differential 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 4-20mA loops. Appending NTX expansion models can interface up to 32 differential current inputs on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2220: Ethernet Analog I/O Modules with 16 Single-ended Current Inputs

    • 16 single-ended current inputs
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2240 modules offer 16 current inputs. Each input supports bipolar and unipolar ranges with 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 4-20mA loops. Appending NTX expansion models can interface up to 64 current inputs on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2230: Ethernet Analog I/O Modules with 8 Differential Voltage Inputs, 2 Discrete I/O

    • 8 differential voltage inputs
    • 2 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2230 modules offer 8 voltage inputs and 2 limit alarms. Each input has true differential 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 0-10V devices. Appending NTX expansion models can interface up to 32 differential voltage inputs on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2240: Ethernet Analog I/O Modules with 16 Single-ended Voltage Inputs

    • 16 single-ended voltage inputs
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2240 modules offer 16 voltage inputs. Each input supports bipolar and unipolar ranges with 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 0-10V devices. Appending NTX expansion models can interface up to 64 voltage inputs on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2310: Ethernet Analog Output Modules with 8 Process Current Outputs

    • 8 process current outputs
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2310 modules offer 8 current outputs. Each output is driven by a 16-bit DAC. NTE Ethernet models provide a compact network interface to control 4-20mA loops. Appending NTX expansion models can interface up to 32 current outputs at a single IP address.
    Select options
  • Compare

    NT2320: Ethernet Analog Output Modules with 8 Process Voltage Outputs

    • 8 process voltage outputs
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2320 modules offer 8 voltage outputs. Each output is driven by a 16-bit DAC. NTE Ethernet models provide a compact network interface to control voltage signal levels. Appending NTX expansion models can interface up to 32 voltage outputs at a single IP address.
    Select options
  • Compare

    XT1210: 8-Channel Differential Analog Current Input Module

    • 0-11mA, 0-20mA, 4-20mA, ±20mA, or 0-20 amps AC Input
    • 8 analog differential current input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1210 offers an isolated Ethernet network interface for up to eight differential current input channels. Isolated differential inputs deliver better measurements, superior noise rejection, and eliminate the need for current loop isolators.
    Select options
  • Compare

    XT1220: 8-Channel Differential Analog Voltage Input Module

    • ±5V, ±10V, 0-5V, 0-10V Input
    • 8 analog differential voltage input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1220 offers an isolated Ethernet network interface for up to eight differential voltage input channels.
    Select options
  • Compare

    XT1230: 16-Channel Single-Ended Analog Current Input Module

    • 0-11mA, 0-20mA, 4-20mA, ±20mA, or 0-20 amps AC Input
    • 16 analog single-ended current input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1230 offers an isolated Ethernet network interface for up to to sixteen single-ended current input channels.
    Select options
  • Compare

    XT1240: 16-Channel Single-ended Analog DC Voltage Input Module

    • Input: ±5V, ±10V, 0-5V, 0-10V
    • 16 analog single-ended voltage input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1240 offers an isolated Ethernet network interface for up to to sixteen single-ended voltage input channels.
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms