Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing 1–16 of 24 results

  • Compare

    TT239: Frequency / Pulse / PWM Input, 12-32V DC Loop Power, 2-Wire Transmitter

    • Multi-range 0Hz to 100KHz frequency input
    • Multi-range 0Hz to 3KHz PWM input
    • 4-20mA output (sink/source)
    • 12-32V DC power
    The TT239 model is a space-saving two-wire transmitter that isolates and converts a frequency, pulse, or pulse-width modulation (PWM) input to a proportional 4-20mA signal. You can select to measure either the input frequency or the duty cycle. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.    
    Select options
  • Compare

    TT339: Frequency / Pulse Input, 12-32V DC Local/Bus Power Transmitter

    • Multi-range 0Hz to 100KHz input
    • Universal current/voltage output
    • 12-32V DC local/bus power
    The TT339 model is a space-saving four-wire transmitter that isolates and converts a frequency or pulse input to a proportional control signal. DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring. Click here to watch a short video highlighting the TT330 Series.
    Select options
  • Compare

    DT235: RTD / Resistance Input Two-Wire Dual Transmitter

    • Dual channels
    • RTD (Pt, Ni, Cu), 0-4500 ohm inputs
    • 4-20mA output (sink/source)
    • 7-32V DC loop power
    The DT235 model is a two-wire dual transmitter that isolates and converts RTD or linear resistance sensor inputs to a proportional 4-20mA control signal.

    Click here to watch a short video highlighting the features of the DT235.

    Select options
  • Compare

    DT335: RTD / Resistance Input Four-wire Dual Transmitter

    • Dual channels
    • RTD (Pt, Ni, Cu) or 0-4500 ohm input
    • 0-20mA, ±10V outputs
    • 6-32V DC local/bus power
    The DT335 model is a four-wire dual transmitter that isolates and converts RTD or linear resistance sensor inputs to proportional control signals. Click here to watch a short video highlighting the features of the DT335.
    Select options
  • Compare

    VPM2000 Series: Loop-Powered Isolator / Alarm with Display

    • Loop-powered Process Meter
    • 4-20mA input/output
    • Solid-state relays
    • Non-incendive, intrinsically safe
    These loop-powered 1/8 DIN digital panel meters provide a convenient and informative display of any 4-20mA signal. A dual line display shows the process value on the top line and the units or a tag on the bottom line. Alternatively, you can display the input in one scale on the top line (e.g. height) and another scale on the bottom (e.g. volume). Click here to watch a short video highlighting the VPM2000 Series.
    Select options
  • Compare

    TT231: RTD / Resistance Input Two-Wire Transmitter

    • 100 ohm Pt RTD or 0-900 ohm input
    • 4-20mA output (sink/source)
    • 12-32V DC loop/local power
    • USB configuration
    The TT231 model is a space-saving two-wire transmitter that converts a 100 ohm Platinum RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    Select options
  • Compare

    VPM3000 Series: Universal Transmitter / Alarm with Display

    • Big, bright display
    • 4-20mA, ±10V, thermocouple, or RTD input
    • 4-20mA, Modbus serial, or alarm relay output options
    Acromag VPM3000 Vertuâ„¢ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications. Learn more about the VPM3000 by watching this short video.
    Select options
  • Compare

    5020-350: Toroidal AC Current Sensor

    • AC Current Sensor to precondition an AC current input signal
    • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
    Select options
  • Compare

    657T, 658T: Single or Dual Channel, RTD Input, Loop-powered Transmitter

    • 100 ohm Pt, 120 ohm Ni, 10 ohm Cu (selectable type) input
    • 4 to 20mA DC output
    • 12-50V DC from output loop power
    • DIP-switch configuration, push-button calibration
    These units accept universal RTD or resistance input signals and output proportional DC current signals. The output can also be linearized to the input sensor signal.
    Select options
  • Compare

    801A Universal TC/RTD/mV Input Intelligent Alarm

    • Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), resistance (0 to 500 ohms) input
    • Single or dual mechanical relay alarm outputs
    • 10-36V DC power
    • Software configured
    • Multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection)
    • On/off controller capability
    IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.
    Select options
  • Compare

    801T: Universal Input Intelligent Temperature Transmitter

    • Thermocouple, RTD, milliVolt, and Resistance Input
    • 0 to 20mA DC, 0 to 10V DC output
    • Limit Alarm
    • 10-36V DC power
    • Software configured
    • Performs linearization, square root extraction, and optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    822A Dual Thermocouple/mV Input Intelligent Alarm

    • 2 input channels, thermocouple (types J, K, T, R, S, E, B, N), or millivolt (±100mV DC) input
    • Dual mechanical relays output
    • 10-36V DC power
    • Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
    IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.
    Select options
  • Compare

    841T: DC Frequency/Pulse Input Intelligent Transmitter

    • 0 to 50KHz, 0 to 65535 pulses input
    • 0 to 20mA DC, 0 to 10V DC output
    • Mechanical alarm relay (25V @ 5A)
    • 10-36V DC power
    • Software configured; pulse counter; signal averaging; optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    924MB: Thermocouple/milliVolt Modbus-RTU Input Module with Limit Alarms

    • 4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt (±100mV DC) input
    • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a four-channel analog input module with four discrete outputs. It filters and linearizes thermocouple inputs while providing isolation between input, output, power, and network circuits. Cold junction compensation and upscale/downscale sensor break detection are standard.  
    Select options
  • Compare

    Agilityâ„¢ Config Tool (Tethered)

    • Tethered Agilityâ„¢ Config Tool mobile application
    • For Acromag SP Series Signal Splitters and most TT Series Transmitters
    • Download available on Google Play for free.
    • Download Windows configuration software from the software tab below.
    Read more
  • Compare

    APM765 Series: Universal Input with Alarm Panel Meter

    • Universal input
    • Isolated 4-20mA and Modbus output options
    • Push-button or PC programmable,
    • 85-265V AC or 90-265V DC power, optional 12-24V AC or 12-36V DC power
    The APM765 displays data collected from process current, DC voltage and temperature inputs. Several output options convert the display into a transmitter with proportional 4-20mA output or a serial communication interface.
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms