Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing all 8 results

  • Compare

    VPM2000 Series: Loop-Powered Isolator / Alarm with Display

    • Loop-powered Process Meter
    • 4-20mA input/output
    • Solid-state relays
    • Non-incendive, intrinsically safe
    These loop-powered 1/8 DIN digital panel meters provide a convenient and informative display of any 4-20mA signal. A dual line display shows the process value on the top line and the units or a tag on the bottom line. Alternatively, you can display the input in one scale on the top line (e.g. height) and another scale on the bottom (e.g. volume). Click here to watch a short video highlighting the VPM2000 Series.
    Select options
  • Compare

    VPM3000 Series: Universal Transmitter / Alarm with Display

    • Big, bright display
    • 4-20mA, ±10V, thermocouple, or RTD input
    • 4-20mA, Modbus serial, or alarm relay output options
    Acromag VPM3000 Vertuâ„¢ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications. Learn more about the VPM3000 by watching this short video.
    Select options
  • Compare

    901MB, 902MB, 903MB: Multi-Channel Modbus-RTU Discrete I/O Modules

    • Active-Low Inputs, Sinking Outputs (Low-Side Switching)
    • 12 input and/or 12 output channels
    • 0 to 35V DC I/O range
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    These modules provide twelve discrete input and/or output channels. Isolation separates the I/O, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus-RTU protocol.    
    Select options
  • Compare

    904MB, 905MB, 906MB: Multi-Channel Discrete I/O Modules

    • Active-High Inputs, Sourcing Outputs (High-Side Switching)
    • 12 input and/or 12 output channels
    • 0 to 35V DC I/O range
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    These modules provide twelve discrete input and/or output channels. Isolation separates the I/O, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus RTU protocol.
    Select options
  • Compare

    951EN, 952EN: Ethernet Analog and Discrete I/O Modules

    • 4 analog inputs
    • 2 analog output
    • 6 discrete I/O channels
    • Ethernet/IP, Modbus TCP/IP
    • i2o peer-to-peer available for Modbus TCP/IP only
    These modules provide an isolated Ethernet network interface for analog and discrete I/O signals. Multi-range analog inputs and outputs support a wide variety of industrial devices. High-resolution, low noise, A/D and D/A converters deliver high accuracy and reliability.
    Select options
  • Compare

    981PB, 982PB, 983PB: Profibus-DP 12-Channel Digital I/O

    • Active-Low Inputs, Sinking Outputs
    • 12 input channels, 0 to 35V DC range
    • 12 to 36V DC
    • High-speed RS-485
    These modules provide an isolated Profibus-DP network interface for twelve discrete input and/or output channels. The outputs provide direct on/off, high/low, or open/close control of industrial devices.
    Select options
  • Compare

    APM765 Series: Universal Input with Alarm Panel Meter

    • Universal input
    • Isolated 4-20mA and Modbus output options
    • Push-button or PC programmable,
    • 85-265V AC or 90-265V DC power, optional 12-24V AC or 12-36V DC power
    The APM765 displays data collected from process current, DC voltage and temperature inputs. Several output options convert the display into a transmitter with proportional 4-20mA output or a serial communication interface.
    Select options
  • Compare

    NT2510 and NT2530: Ethernet Multi-Function I/O Modules

    • 4 analog inputs
    • 2 analog outputs
    • 4 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2510 modules offer 4 current inputs, 2 current outputs, and 4 discrete I/O channels. NT2530 models have voltage input. NTE Ethernet models provide a network interface to monitor and control I/O signals. Appending NTX expansion models can interface up to 24 analog and 16 discrete I/O on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.