Acromag remote I/O modules feature signal conditioners and network I/OÂ for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
TT239: Frequency / Pulse / PWM Input, 12-32V DC Loop Power, 2-Wire Transmitter
Multi-range 0Hz to 100KHz frequency input
Multi-range 0Hz to 3KHz PWM input
4-20mA output (sink/source)
12-32V DC power
The TT239 model is a space-saving two-wire transmitter that isolates and converts a frequency, pulse, or pulse-width modulation (PWM) input to a proportional 4-20mA signal. You can select to measure either the input frequency or the duty cycle. Power is received from the output loop current or a DC supply when using a three-wire connection.
Click here to watch a short AcroMaggie video highlighting the TT230 Series.
TT339: Frequency / Pulse Input, 12-32V DC Local/Bus Power Transmitter
Multi-range 0Hz to 100KHz input
Universal current/voltage output
12-32V DC local/bus power
The TT339 model is a space-saving four-wire transmitter that isolates and converts a frequency or pulse input to a proportional control signal. DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring.
Click here to watch a short video highlighting the TT330 Series.
NT2210: Ethernet Analog I/O Modules with 8 Differential Current Inputs, 2 Discrete I/O
8 differential current inputs
2 discrete I/O
Ethernet I/O plus Expansion I/O
Multi-protocol support
NT2210 modules offer 8 current inputs and 2 limit alarms. Each input has true differential 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 4-20mA loops. Appending NTX expansion models can interface up to 32 differential current inputs on a single IP address.
Click here to watch a short video highlighting the features of the BusWorks NT Series.
NT2220: Ethernet Analog I/O Modules with 16 Single-ended Current Inputs
16 single-ended current inputs
Ethernet I/O plus Expansion I/O
Multi-protocol support
NT2240 modules offer 16 current inputs. Each input supports bipolar and unipolar ranges with 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 4-20mA loops. Appending NTX expansion models can interface up to 64 current inputs on a single IP address.
Click here to watch a short video highlighting the features of the BusWorks NT Series.
NT2230: Ethernet Analog I/O Modules with 8 Differential Voltage Inputs, 2 Discrete I/O
8 differential voltage inputs
2 discrete I/O
Ethernet I/O plus Expansion I/O
Multi-protocol support
NT2230 modules offer 8 voltage inputs and 2 limit alarms. Each input has true differential 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 0-10V devices. Appending NTX expansion models can interface up to 32 differential voltage inputs on a single IP address.
Click here to watch a short video highlighting the features of the BusWorks NT Series.
NT2240: Ethernet Analog I/O Modules with 16 Single-ended Voltage Inputs
16 single-ended voltage inputs
Ethernet I/O plus Expansion I/O
Multi-protocol support
NT2240 modules offer 16 voltage inputs. Each input supports bipolar and unipolar ranges with 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 0-10V devices. Appending NTX expansion models can interface up to 64 voltage inputs on a single IP address.
Click here to watch a short video highlighting the features of the BusWorks NT Series.
NT2310: Ethernet Analog Output Modules with 8 Process Current Outputs
8 process current outputs
Ethernet I/O plus Expansion I/O
Multi-protocol support
NT2310 modules offer 8 current outputs. Each output is driven by a 16-bit DAC. NTE Ethernet models provide a compact network interface to control 4-20mA loops. Appending NTX expansion models can interface up to 32 current outputs at a single IP address.
NT2320: Ethernet Analog Output Modules with 8 Process Voltage Outputs
8 process voltage outputs
Ethernet I/O plus Expansion I/O
Multi-protocol support
NT2320 modules offer 8 voltage outputs. Each output is driven by a 16-bit DAC. NTE Ethernet models provide a compact network interface to control voltage signal levels. Appending NTX expansion models can interface up to 32 voltage outputs at a single IP address.
XT1210: 8-Channel Differential Analog Current Input Module
0-11mA, 0-20mA, 4-20mA, ±20mA, or 0-20 amps AC Input
8 analog differential current input channels
12 to 32V DC Power (2.8W)
Modbus TCP/IP, Ethernet/IP, Profinet
i2o® peer-to-peer available for Modbus TCP/IP only
The XT1210 offers an Ethernet network interface for up to eight differential current input channels. Differential inputs deliver better measurements and superior noise rejection.
VPM2000 Series: Loop-Powered Isolator / Alarm with Display
Loop-powered Process Meter
4-20mA input/output
Solid-state relays
Non-incendive, intrinsically safe
These loop-powered 1/8 DIN digital panel meters provide a convenient and informative display of any 4-20mA signal. A dual line display shows the process value on the top line and the units or a tag on the bottom line. Alternatively, you can display the input in one scale on the top line (e.g. height) and another scale on the bottom (e.g. volume).
Click here to watch a short video highlighting the VPM2000 Series.
XT1530: Analog Output & Digital I/O Ethernet Modules
4 Analog DC Current Outputs
4 Discrete Voltage I/O Channels
12 to 32V DC Power (2.8W)
Modbus TCP/IP, Ethernet/IP, Profinet
i2o® peer-to-peer available for Modbus TCP/IP only
The XT1530 interfaces analog output and discrete I/O signals between measurement and control devices over Ethernet. Discrete I/O are individually configurable for input or high-side switched output operation.
VPM3000 Series: Universal Transmitter / Alarm with Display
Big, bright display
4-20mA, ±10V, thermocouple, or RTD input
4-20mA, Modbus serial, or alarm relay output options
Acromag VPM3000 Vertuâ„¢ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications.
Learn more about the VPM3000 by watching this short video.
XT1540: Analog Output & Digital I/O Ethernet Modules
8 Analog DC Voltage Outputs ±10V (calibrated), ±5V (sub-range)
4 Discrete Voltage I/O Channels 0-32V DC
12 to 32V DC Power (2.8W)
Modbus TCP/IP, Ethernet/IP, Profinet
i2o® peer-to-peer available for Modbus TCP/IP only
The XT1540 interfaces analog output and discrete I/O signals between measurement and control devices over Ethernet. Discrete I/O are individually configurable for input or high-side switched output operation.
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.