Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing all 15 results

  • Compare

    NT2610: Ethernet Thermocouple milliVolt Input Modules with Discrete I/O

    • 8 thermocouple / mV inputs
    • 2 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2610 Ethernet thermocouple modules and Ethernet millivolt modules offer 8 TC / mV inputs and 2 bidirectional discrete digital I/O channels. Each input can support a variety of sensor types. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2620: Ethernet RTD/Resistance Input Modules with Discrete I/O

    • 4 RTD/resistance inputs
    • 2 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2620 modules offer 4 RTD/resistance inputs and 2 bidirectional discrete digital I/O channels. Each input can support RTD or resistance sensor types. NTE Ethernet models provide a network interface to monitor temperature levels. Click here to watch a short video highlighting the benefits of the NT1620.
    Select options
  • Compare

    800C-SIP: IntelliPack Configuration Software

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RJ11 Adapter
    • Interface Cable
    Acromag’s configuration software is the key to the IntelliPack’s easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
    Select options
  • Compare

    841T: DC Frequency/Pulse Input Intelligent Transmitter

    • 0 to 50KHz, 0 to 65535 pulses input
    • 0 to 20mA DC, 0 to 10V DC output
    • Mechanical alarm relay (25V @ 5A)
    • 10-36V DC power
    • Software configured; pulse counter; signal averaging; optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    942MB: Frequency/Pulse Counter Modbus-RTU Input Modules with Periodic or Pulse Waveform Input

    • 2 input channels, 0 to 50KHz in 3 selectable ranges: Amplitudes up to 140V AC peak, Amplitudes up to 200V peak, Pulse counter range of 0 to 65535
    • Solid-state discrete output relays (1A DC loads), 0 to 48V DC
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a two-channel analog input module with discrete outputs and Modbus communication. It conditions periodic or pulse waveform inputs and provides solid-state relays for limit alarms or ON/OFF control.
    Select options
  • Compare

    961PB, 962PB: 6-Channel Differential Profibus-DP Input Modules

    • DC Current or DC Voltage Signals
    • 6 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±78mV to ±10V DC with eight range options
    • 12 to 36V DC power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for six analog input channels. Differential inputs eliminate ground loops and thus the need for isolators in any applications.
    Select options
  • Compare

    963PB, 964PB: 12-Channel Single-Ended Input Profibus-DP Modules

    • DC Current or DC Voltage Signals
    • 12 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±1V, ±5V or ±10V DC
    • 12 to 36V DC power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for twelve analog input channels. Compact design saves space and lowers system costs.
    Select options
  • Compare

    965EN: Ethernet Thermocouple milliVolt Input Modules

    • 4 or 6-channel thermocouple/milliVolt input
    • Ethernet/IP, Modbus TCP/IP
    • i2o peer-to-peer available for Modbus TCP/IP 6-channel only
    These modules provide an isolated Ethernet network interface for up to six input channels. Differential inputs eliminate ground noise and each terminal block includes a cold junction compensation (CJC) sensor for more precise temperature measurements. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.    
    Select options
  • Compare

    965PB: 4 or 6-Channel Thermocouple/mV Input Profibus-DP Modules

    • Thermocouple or Millivolt Signals
    • 4 or 6 input channels, thermocouple or DC millivolts (user-selectable)
    • 12 to 36V DC  power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for up to six input channels. Differential inputs eliminate ground noise.
    Select options
  • Compare

    966EN: Ethernet RTD Resistance Input Modules

    • 4 or 6-channel RTD/resistance input
    • Ethernet/IP, Modbus TCP/IP
    • i2o peer-to-peer available for Modbus TCP/IP 6-channel only
    These modules provide an isolated Ethernet network interface for up to six input channels. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability. Three-way isolation further improves the system performance.  
    Select options
  • Compare

    966PB: 4 or 6-Channel RTD/Resistance Input Profibus-DP Modules

    • RTD or Resistance Signals
    • 4 or 6 input channels, Platinum 100 ohm, Nickel 120 ohm, Copper 10 ohm; 0 to 500 ohms resistance
    • 12 to 36V DC power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for up to six input channels. Multi-range inputs accept signals from a variety of sensors and devices.
    Select options
  • Compare

    972PB, 973PB: Analog Output Profibus-DP - RS485 Modules

    • 0 to 1mA, 0 to 20mA, or 4 to 20mA DC Current Output; 0 to 1V, 0 to 5V or 0 to 10V DC Output
    • 12 to 36V DC Power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide up to six channels of analog output. Multi-range outputs support a wide variety of industrial devices.
    Select options
  • Compare

    XTA-120V-6: Solid-State Relay Input Modules

    • 6 optocoupler channels
    • 120V AC/DC input with optical isolation
    • Universal 5/12/24V logic output
    The XTA-120V-6 optocoupler module provides six individually isolated 120V AC/DC digital (discrete) inputs to sense on/off levels and drive open-drain outputs. It is intended for use with BusWorks XT Series discrete I/O and other digital input modules to monitor contact closures or mains power supply high/low voltage levels.
    Select options
  • Compare

    XTA-MRNO-6: Mechanical Relay Output Modules

    • 6 digital I/O channels
    •  Universal 5/12/24V logic inputs
    •  Form A, 250V AC / 30V DC @ 5A relay outputs
    The XTA-MRNO-6 is an interposing relay module with six digital inputs and six mechanical relay outputs. It is intended for use with BusWorks XT Series discrete I/O or other digital output modules for the purpose of driving high energy loads.
    Select options
  • Compare

    250T-AC, 350T-AC, 450T-AC: Loop, DC, or AC-Power Transmitter

    • Transmitter, Loop, DC, or AC-Power
    • AC Voltage or AC Current Input
    • DC Voltage or DC Current Output
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms