Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing 1–16 of 25 results

  • Compare

    DT235: RTD / Resistance Input Two-Wire Dual Transmitter

    • Dual channels
    • RTD (Pt, Ni, Cu), 0-4500 ohm inputs
    • 4-20mA output (sink/source)
    • 7-32V DC loop power
    The DT235 model is a two-wire dual transmitter that isolates and converts RTD or linear resistance sensor inputs to a proportional 4-20mA control signal.

    Click here to watch a short video highlighting the features of the DT235.

    Select options
  • Compare

    DT335: RTD / Resistance Input Four-wire Dual Transmitter

    • Dual channels
    • RTD (Pt, Ni, Cu) or 0-4500 ohm input
    • 0-20mA, ±10V outputs
    • 6-32V DC local/bus power
    The DT335 model is a four-wire dual transmitter that isolates and converts RTD or linear resistance sensor inputs to proportional control signals. Click here to watch a short video highlighting the features of the DT335.
    Select options
  • Compare

    NT2610: Ethernet Thermocouple milliVolt Input Modules with Discrete I/O

    • 8 thermocouple / mV inputs
    • 2 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2610 Ethernet thermocouple modules and Ethernet millivolt modules offer 8 TC / mV inputs and 2 bidirectional discrete digital I/O channels. Each input can support a variety of sensor types. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2620: Ethernet RTD/Resistance Input Modules with Discrete I/O

    • 4 RTD/resistance inputs
    • 2 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2620 modules offer 4 RTD/resistance inputs and 2 bidirectional discrete digital I/O channels. Each input can support RTD or resistance sensor types. NTE Ethernet models provide a network interface to monitor temperature levels. Click here to watch a short video highlighting the benefits of the NT1620.
    Select options
  • Compare

    TT231: RTD / Resistance Input Two-Wire Transmitter

    • 100 ohm Pt RTD or 0-900 ohm input
    • 4-20mA output (sink/source)
    • 12-32V DC loop/local power
    • USB configuration
    The TT231 model is a space-saving two-wire transmitter that converts a 100 ohm Platinum RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    Select options
  • Compare

    VPM3000 Series: Universal Transmitter / Alarm with Display

    • Big, bright display
    • 4-20mA, ±10V, thermocouple, or RTD input
    • 4-20mA, Modbus serial, or alarm relay output options
    Acromag VPM3000 Vertu™ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications. Learn more about the VPM3000 by watching this short video.
    Select options
  • Compare

    20RM-16-DIN: 19” rack-mount kit with DIN rail

    • 19" rack-mount kit with DIN rail
    Select options
  • Compare

    350T NEMA Enclosure

    Mounting Accessories NEMA-4 and MEMA-12 Enclosures
    Read more
  • Compare

    657T, 658T: Single or Dual Channel, RTD Input, Loop-powered Transmitter

    • 100 ohm Pt, 120 ohm Ni, 10 ohm Cu (selectable type) input
    • 4 to 20mA DC output
    • 12-50V DC from output loop power
    • DIP-switch configuration, push-button calibration
    These units accept universal RTD or resistance input signals and output proportional DC current signals. The output can also be linearized to the input sensor signal.
    Select options
  • Compare

    801T: Universal Input Intelligent Temperature Transmitter

    • Thermocouple, RTD, milliVolt, and Resistance Input
    • 0 to 20mA DC, 0 to 10V DC output
    • Limit Alarm
    • 10-36V DC power
    • Software configured
    • Performs linearization, square root extraction, and optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    841T: DC Frequency/Pulse Input Intelligent Transmitter

    • 0 to 50KHz, 0 to 65535 pulses input
    • 0 to 20mA DC, 0 to 10V DC output
    • Mechanical alarm relay (25V @ 5A)
    • 10-36V DC power
    • Software configured; pulse counter; signal averaging; optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    892M, 894M: DC Voltage/Current Output Math Module

    • 2 or 4 input channels, 0 to 20mA DC, 0 to 10V DC (selectable ranges)
    • 0 to 20mA DC, 0 to 10V DC (selectable ranges) output
    • 10-36V DC power
    • Software configured, computes arithmetic operations, evaluates conditional and Boolean arguments, executes track & hold functions
    IntelliPack math modules perform complex mathematical computations and convert DC input signals to scaled DC or frequency outputs. They are ideal for isolating and interfacing analog signals to a PLC or controller as a voltage, current, or a pulsed input.
    Select options
  • Compare

    942MB: Frequency/Pulse Counter Modbus-RTU Input Modules with Periodic or Pulse Waveform Input

    • 2 input channels, 0 to 50KHz in 3 selectable ranges: Amplitudes up to 140V AC peak, Amplitudes up to 200V peak, Pulse counter range of 0 to 65535
    • Solid-state discrete output relays (1A DC loads), 0 to 48V DC
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a two-channel analog input module with discrete outputs and Modbus communication. It conditions periodic or pulse waveform inputs and provides solid-state relays for limit alarms or ON/OFF control.
    Select options
  • Compare

    965EN: Ethernet Thermocouple milliVolt Input Modules

    • 4 or 6-channel thermocouple/milliVolt input
    • Ethernet/IP, Modbus TCP/IP
    • i2o peer-to-peer available for Modbus TCP/IP 6-channel only
    These modules provide an isolated Ethernet network interface for up to six input channels. Differential inputs eliminate ground noise and each terminal block includes a cold junction compensation (CJC) sensor for more precise temperature measurements. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.    
    Select options
  • Compare

    966EN: Ethernet RTD Resistance Input Modules

    • 4 or 6-channel RTD/resistance input
    • Ethernet/IP, Modbus TCP/IP
    • i2o peer-to-peer available for Modbus TCP/IP 6-channel only
    These modules provide an isolated Ethernet network interface for up to six input channels. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability. Three-way isolation further improves the system performance.  
    Select options
  • Compare

    ACC1014: Flat Pack Mounting Kit

    • Surface mount for 250T, 260A and 270i series
    • Snaptrack mount 250T, 260A and 270i series
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms