Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing all 14 results

  • Compare

    VPM3000 Series: Universal Transmitter / Alarm with Display

    • Big, bright display
    • 4-20mA, ±10V, thermocouple, or RTD input
    • 4-20mA, Modbus serial, or alarm relay output options
    Acromag VPM3000 Vertuâ„¢ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications. Learn more about the VPM3000 by watching this short video.
    Select options
  • Compare

    811A, 812A: Intelligent Alarm; DC Voltage/Current Input

    • ±100V or 0 to 22mA DC input ranges or 2 input channels, ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
    • Single or dual mechanical relays
    • 10-36V DC power
    • Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
    IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.  
    Select options
  • Compare

    892M, 894M: DC Voltage/Current Output Math Module

    • 2 or 4 input channels, 0 to 20mA DC, 0 to 10V DC (selectable ranges)
    • 0 to 20mA DC, 0 to 10V DC (selectable ranges) output
    • 10-36V DC power
    • Software configured, computes arithmetic operations, evaluates conditional and Boolean arguments, executes track & hold functions
    IntelliPack math modules perform complex mathematical computations and convert DC input signals to scaled DC or frequency outputs. They are ideal for isolating and interfacing analog signals to a PLC or controller as a voltage, current, or a pulsed input.
    Select options
  • Compare

    895M, 896M: DC Input, Frequency Output Math Module

    • 0 to 20mA DC, 0 to 10V DC (selectable ranges), 896M 2 channels input
    • 0 to 10KHz, 0 to 36,000 counts/hr Frequency output, 896M 2 channels
    • Solid-state relay (60V DC @ 500mA) control output
    • 10-36V DC power
    • Software configured, ideal for integrator/totalizer applications, computes arithmetic operations, conditional arguments, track & hold functions
    IntelliPack math modules perform complex mathematical computations and convert DC input signals to scaled DC or frequency outputs.
    Select options
  • Compare

    913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms

    • 4 input channels
    • 0 to 20mA DC (0 to 20A AC with AC sensor) or ±10V DC input range
    • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus RTU high-speed RS-485
    This signal conditioner is a four-channel analog input module with four discrete outputs. It provides isolation between input, output, power, and network circuits.
    Select options
  • Compare

    961PB, 962PB: 6-Channel Differential Profibus-DP Input Modules

    • DC Current or DC Voltage Signals
    • 6 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±78mV to ±10V DC with eight range options
    • 12 to 36V DC power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for six analog input channels. Differential inputs eliminate ground loops and thus the need for isolators in any applications.
    Select options
  • Compare

    963PB, 964PB: 12-Channel Single-Ended Input Profibus-DP Modules

    • DC Current or DC Voltage Signals
    • 12 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±1V, ±5V or ±10V DC
    • 12 to 36V DC power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for twelve analog input channels. Compact design saves space and lowers system costs.
    Select options
  • Compare

    965PB: 4 or 6-Channel Thermocouple/mV Input Profibus-DP Modules

    • Thermocouple or Millivolt Signals
    • 4 or 6 input channels, thermocouple or DC millivolts (user-selectable)
    • 12 to 36V DC  power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for up to six input channels. Differential inputs eliminate ground noise.
    Select options
  • Compare

    966PB: 4 or 6-Channel RTD/Resistance Input Profibus-DP Modules

    • RTD or Resistance Signals
    • 4 or 6 input channels, Platinum 100 ohm, Nickel 120 ohm, Copper 10 ohm; 0 to 500 ohms resistance
    • 12 to 36V DC power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for up to six input channels. Multi-range inputs accept signals from a variety of sensors and devices.
    Select options
  • Compare

    972PB, 973PB: Analog Output Profibus-DP - RS485 Modules

    • 0 to 1mA, 0 to 20mA, or 4 to 20mA DC Current Output; 0 to 1V, 0 to 5V or 0 to 10V DC Output
    • 12 to 36V DC Power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide up to six channels of analog output. Multi-range outputs support a wide variety of industrial devices.
    Select options
  • Compare

    Agilityâ„¢ Config Tool (Tethered)

    • Tethered Agilityâ„¢ Config Tool mobile application
    • For Acromag SP Series Signal Splitters and most TT Series Transmitters
    • Download available on Google Play for free.
    • Download Windows configuration software from the software tab below.
    Read more
  • Compare

    TTC-SIP: Software

    • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
    • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
    • Easy setup and digital calibration via USB with Windows configuration software.
    • Download the configuration software only - from the Software Tab
    Select options
  • Compare

    260A: Limit Alarm; DC Current Input, Loop-Powered

    • 4 to 20mA DC input
    • Single mechanical relay output
    • 4.5V DC from input loop power
    • Hi/lo fail-safe option trips alarms above or below set-point
    The 260A accepts a 4 to 20mA input signal and provides a dry contact relay output if the input exceeds a user-defined set-point limit. Power is received from the input loop.        
    Select options
  • Compare

    361A, 461A: Limit Alarm; DC Voltage/Current Input, AC or DC-Powered

    • 0 to 20mA DC, 0 to 100V DC, AC current (with optional sensor) input
    • Single or dual mechanical relays output
    • 10-36V DC or 115/230V AC power
    • 100% adjustable set-point, hi/lo fail-safe operation, jumper-selectable voltage/current input
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms