Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing all 16 results

  • Compare

    VPM3000 Series: Universal Transmitter / Alarm with Display

    • Big, bright display
    • 4-20mA, ±10V, thermocouple, or RTD input
    • 4-20mA, Modbus serial, or alarm relay output options
    Acromag VPM3000 Vertuâ„¢ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications. Learn more about the VPM3000 by watching this short video.
    Select options
  • Compare

    800C-SIP: IntelliPack Configuration Software

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RJ11 Adapter
    • Interface Cable
    Acromag’s configuration software is the key to the IntelliPack’s easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
    Select options
  • Compare

    811A, 812A: Intelligent Alarm; DC Voltage/Current Input

    • ±100V or 0 to 22mA DC input ranges or 2 input channels, ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
    • Single or dual mechanical relays
    • 10-36V DC power
    • Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
    IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.  
    Select options
  • Compare

    900EN: 5-Port Ethernet Switch

    • 10/100Mbps
    • 15 to 36V DC power supply required
    • Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
    Acromag’s five-port Ethernet switch is specially designed for use in industrial applications. Rugged construction and a variety of security features ensure reliable operation under demanding conditions.
    Select options
  • Compare

    913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms

    • 4 input channels
    • 0 to 20mA DC (0 to 20A AC with AC sensor) or ±10V DC input range
    • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus RTU high-speed RS-485
    This signal conditioner is a four-channel analog input module with four discrete outputs. It provides isolation between input, output, power, and network circuits.
    Select options
  • Compare

    917MB, 918MB: DC Current/Voltage Modbus-RTU Output Modules with Discrete Outputs

    • 4 analog output channels
    • 0 to 20mA or 0 to 10V DC output range
    • 4 discrete output channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus RTU high-speed RS-485
    These modules drive four analog output channels and also feature four discrete outputs for on/off control. Isolation separates the output, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus RTU protocol.
    Select options
  • Compare

    924MB: Thermocouple/milliVolt Modbus-RTU Input Module with Limit Alarms

    • 4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt (±100mV DC) input
    • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a four-channel analog input module with four discrete outputs. It filters and linearizes thermocouple inputs while providing isolation between input, output, power, and network circuits. Cold junction compensation and upscale/downscale sensor break detection are standard.  
    Select options
  • Compare

    932MB, 934MB: RTD/Resistance Modbus-RTU Input Modules with Limit Alarms or Discrete Outputs

    • 2 or 4 input channels, RTD (100 ohm Pt, 120 ohm Ni, 10 ohm Cu) or resistance (0 to 500 ohms) input
    • Solid-state relays discrete output, Form A, SPST-NO
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a dual or quad-channel analog input module with one discrete/relay output per input channel and a Modbus interface. It filters and linearizes RTD or resistance inputs while providing isolation between input, output, power, and network circuits.
    Select options
  • Compare

    942MB: Frequency/Pulse Counter Modbus-RTU Input Modules with Periodic or Pulse Waveform Input

    • 2 input channels, 0 to 50KHz in 3 selectable ranges: Amplitudes up to 140V AC peak, Amplitudes up to 200V peak, Pulse counter range of 0 to 65535
    • Solid-state discrete output relays (1A DC loads), 0 to 48V DC
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a two-channel analog input module with discrete outputs and Modbus communication. It conditions periodic or pulse waveform inputs and provides solid-state relays for limit alarms or ON/OFF control.
    Select options
  • Compare

    Agilityâ„¢ Config Tool (Tethered)

    • Tethered Agilityâ„¢ Config Tool mobile application
    • For Acromag SP Series Signal Splitters and most TT Series Transmitters
    • Download available on Google Play for free.
    • Download Windows configuration software from the software tab below.
    Read more
  • Compare

    LNX-0702G: 7-Port Gigabit Ethernet with SFP Fiber Ports

    • 5-Port 10/100/1000TX and 2-port 100/1000 Fx SFP Slots
    • Auto MDI/MDI-X Function
    • 10Gbps Back-Plane
    Select options
  • Compare

    Profibus-DP GSD Files

    • Download GSD files from the Software Tab
    Read more
  • Compare

    ST13C-SIP

    • Configuration software
    • USB isolator
    • Two USB cables
    • One kit recommended per customer
       
    Select options
  • Compare

    TTC-SIP: Software

    • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
    • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
    • Easy setup and digital calibration via USB with Windows configuration software.
    • Download the configuration software only - from the Software Tab
    Select options
  • Compare

    4683 Series: RS485-to-RS485 Network Repeater

    • Designed for use with Johnson Controls N2 or BACnet MS/TP bus
    • 115V AC ±10%, 50/60 Hz, 0.05A or 230V AC ±10%, 50/60 Hz, 0.03A or 24V AC ±10%, 50/60 Hz, 0.18A typical power
    • Operating temperature: -25 to 70° C (-13 to 158° F)
    4683-TTM-1F: 115V AC Power 4683-TTM-2F: 230V AC Power 4683-TTM-3F: 24V AC Power
    Select options
  • Compare

    361A, 461A: Limit Alarm; DC Voltage/Current Input, AC or DC-Powered

    • 0 to 20mA DC, 0 to 100V DC, AC current (with optional sensor) input
    • Single or dual mechanical relays output
    • 10-36V DC or 115/230V AC power
    • 100% adjustable set-point, hi/lo fail-safe operation, jumper-selectable voltage/current input
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms