Acromag remote I/O modules feature signal conditioners and network I/OÂ for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
Showing 1–16 of 22 results
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
633T: AC/DC-Powered Signal Splitter
- Single input, dual output (splitter)
- 12-36V DC SELV, 90-250V AC
- Provides two identical outputs from one input signal
-
800C-SIP: IntelliPack Configuration Software
- Configuration Software
- USB-to-RS232 Adapter
- RS232-to-RJ11 Adapter
- Interface Cable
-
801A Universal TC/RTD/mV Input Intelligent Alarm
- Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), resistance (0 to 500 ohms) input
- Single or dual mechanical relay alarm outputs
- 10-36V DC power
- Software configured
- Multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection)
- On/off controller capability
-
801T: Universal Input Intelligent Temperature Transmitter
- Thermocouple, RTD, milliVolt, and Resistance Input
- 0 to 20mA DC, 0 to 10V DC output
- Limit Alarm
- 10-36V DC power
- Software configured
- Performs linearization, square root extraction, and optional limit alarm functions
-
822A Dual Thermocouple/mV Input Intelligent Alarm
- 2 input channels, thermocouple (types J, K, T, R, S, E, B, N), or millivolt (±100mV DC) input
- Dual mechanical relays output
- 10-36V DC power
- Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
-
924MB: Thermocouple/milliVolt Modbus-RTU Input Module with Limit Alarms
- 4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt (±100mV DC) input
- 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
961PB, 962PB: 6-Channel Differential Profibus-DP Input Modules
- DC Current or DC Voltage Signals
- 6 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±78mV to ±10V DC with eight range options
- 12 to 36V DC power
- Profibus-DP, RS-485 network up to 12Mbaud
-
963PB, 964PB: 12-Channel Single-Ended Input Profibus-DP Modules
- DC Current or DC Voltage Signals
- 12 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±1V, ±5V or ±10V DC
- 12 to 36V DC power
- Profibus-DP, RS-485 network up to 12Mbaud
-
965PB: 4 or 6-Channel Thermocouple/mV Input Profibus-DP Modules
- Thermocouple or Millivolt Signals
- 4 or 6 input channels, thermocouple or DC millivolts (user-selectable)
- 12 to 36V DCÂ power
- Profibus-DP, RS-485 network up to 12Mbaud
-
966PB: 4 or 6-Channel RTD/Resistance Input Profibus-DP Modules
- RTD or Resistance Signals
- 4 or 6 input channels, Platinum 100 ohm, Nickel 120 ohm, Copper 10 ohm; 0 to 500 ohms resistance
- 12 to 36V DC power
- Profibus-DP, RS-485 network up to 12Mbaud
-
972PB, 973PB: Analog Output Profibus-DP - RS485 Modules
- 0 to 1mA, 0 to 20mA, or 4 to 20mA DC Current Output; 0 to 1V, 0 to 5V or 0 to 10V DC Output
- 12 to 36V DC Power
- Profibus-DP, RS-485 network up to 12Mbaud
-
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
-
SP333: Four-Wire Thermocouple / milliVolt Splitter
- Universal thermocouple or ±100mV input
- 0-20mA, ±10V or 0-10V outputs
- 6-32V DC external power
-
SP336: Four-Wire Current / milliVolt Signal Splitter
- DC current and low voltage input
- 0-20mA, ±10V outputs
- 6-32V DC external power
-
SP337: Four-wire Process Voltage Input Signal Splitter
- Multi-range ±1V, ±5V, or ±10V input
- 0-20mA, ±10V or 0-10V outputs
- 6-32V DC external power
Signal Conditioning Selection Guide Videos
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.