Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing 1–16 of 22 results

  • Compare

    20RM-16-DIN: 19” rack-mount kit with DIN rail

    • 19" rack-mount kit with DIN rail
    Select options
  • Compare

    350T NEMA Enclosure

    Mounting Accessories NEMA-4 and MEMA-12 Enclosures
    Read more
  • Compare

    633T: AC/DC-Powered Signal Splitter

    • Single input, dual output (splitter)
    • 12-36V DC SELV, 90-250V AC
    • Provides two identical outputs from one input signal
    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels. Galvanic isolation eliminates ground loops, reduces noise, and blocks transient signals.
    Select options
  • Compare

    801T: Universal Input Intelligent Temperature Transmitter

    • Thermocouple, RTD, milliVolt, and Resistance Input
    • 0 to 20mA DC, 0 to 10V DC output
    • Limit Alarm
    • 10-36V DC power
    • Software configured
    • Performs linearization, square root extraction, and optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    841T: DC Frequency/Pulse Input Intelligent Transmitter

    • 0 to 50KHz, 0 to 65535 pulses input
    • 0 to 20mA DC, 0 to 10V DC output
    • Mechanical alarm relay (25V @ 5A)
    • 10-36V DC power
    • Software configured; pulse counter; signal averaging; optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    942MB: Frequency/Pulse Counter Modbus-RTU Input Modules with Periodic or Pulse Waveform Input

    • 2 input channels, 0 to 50KHz in 3 selectable ranges: Amplitudes up to 140V AC peak, Amplitudes up to 200V peak, Pulse counter range of 0 to 65535
    • Solid-state discrete output relays (1A DC loads), 0 to 48V DC
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a two-channel analog input module with discrete outputs and Modbus communication. It conditions periodic or pulse waveform inputs and provides solid-state relays for limit alarms or ON/OFF control.
    Select options
  • Compare

    961PB, 962PB: 6-Channel Differential Profibus-DP Input Modules

    • DC Current or DC Voltage Signals
    • 6 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±78mV to ±10V DC with eight range options
    • 12 to 36V DC power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for six analog input channels. Differential inputs eliminate ground loops and thus the need for isolators in any applications.
    Select options
  • Compare

    963PB, 964PB: 12-Channel Single-Ended Input Profibus-DP Modules

    • DC Current or DC Voltage Signals
    • 12 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±1V, ±5V or ±10V DC
    • 12 to 36V DC power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for twelve analog input channels. Compact design saves space and lowers system costs.
    Select options
  • Compare

    965PB: 4 or 6-Channel Thermocouple/mV Input Profibus-DP Modules

    • Thermocouple or Millivolt Signals
    • 4 or 6 input channels, thermocouple or DC millivolts (user-selectable)
    • 12 to 36V DC  power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for up to six input channels. Differential inputs eliminate ground noise.
    Select options
  • Compare

    966PB: 4 or 6-Channel RTD/Resistance Input Profibus-DP Modules

    • RTD or Resistance Signals
    • 4 or 6 input channels, Platinum 100 ohm, Nickel 120 ohm, Copper 10 ohm; 0 to 500 ohms resistance
    • 12 to 36V DC power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for up to six input channels. Multi-range inputs accept signals from a variety of sensors and devices.
    Select options
  • Compare

    972PB, 973PB: Analog Output Profibus-DP - RS485 Modules

    • 0 to 1mA, 0 to 20mA, or 4 to 20mA DC Current Output; 0 to 1V, 0 to 5V or 0 to 10V DC Output
    • 12 to 36V DC Power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide up to six channels of analog output. Multi-range outputs support a wide variety of industrial devices.
    Select options
  • Compare

    ACC1014: Flat Pack Mounting Kit

    • Surface mount for 250T, 260A and 270i series
    • Snaptrack mount 250T, 260A and 270i series
    Select options
  • Compare

    DIN Rail: Type T

    • DIN Rail Strip, Type T
    Select options
  • Compare

    EtherStax Mounting Kits

    • EtherStax mounting accessories
    Select options
  • Compare

    SP333: Four-Wire Thermocouple / milliVolt Splitter

    • Universal thermocouple or ±100mV input
    • 0-20mA, ±10V or 0-10V outputs
    • 6-32V DC external power
    The SP333 is a high-performance signal splitter that converts one millivolt or thermocouple input into two isolated proportional control signals. A variety of current and voltage output ranges are supported. Click here to watch a short video highlighting the features of the Acromag SP Series.
    Select options
  • Compare

    SP336: Four-Wire Current / milliVolt Signal Splitter

    • DC current and low voltage input
    • 0-20mA, ±10V outputs
    • 6-32V DC external power
    The SP336 is a high-performance signal splitter that converts one DC current or millivolt input into two isolated proportional control signals. A variety of current and voltage output ranges are supported. Power connects on a terminal block, a rail bus, or both for redundancy. Click here to watch a short video highlighting the features of the Acromag SP Series.
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms