Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing 1–16 of 40 results

  • Compare

    TT239: Frequency / Pulse / PWM Input, 12-32V DC Loop Power, 2-Wire Transmitter

    • Multi-range 0Hz to 100KHz frequency input
    • Multi-range 0Hz to 3KHz PWM input
    • 4-20mA output (sink/source)
    • 12-32V DC power
    The TT239 model is a space-saving two-wire transmitter that isolates and converts a frequency, pulse, or pulse-width modulation (PWM) input to a proportional 4-20mA signal. You can select to measure either the input frequency or the duty cycle. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.    
    Select options
  • Compare

    TT339: Frequency / Pulse Input, 12-32V DC Local/Bus Power Transmitter

    • Multi-range 0Hz to 100KHz input
    • Universal current/voltage output
    • 12-32V DC local/bus power
    The TT339 model is a space-saving four-wire transmitter that isolates and converts a frequency or pulse input to a proportional control signal. DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring. Click here to watch a short video highlighting the TT330 Series.
    Select options
  • Compare

    NT2210: Ethernet Analog I/O Modules with 8 Differential Current Inputs, 2 Discrete I/O

    • 8 differential current inputs
    • 2 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2210 modules offer 8 current inputs and 2 limit alarms. Each input has true differential 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 4-20mA loops. Appending NTX expansion models can interface up to 32 differential current inputs on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2220: Ethernet Analog I/O Modules with 16 Single-ended Current Inputs

    • 16 single-ended current inputs
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2240 modules offer 16 current inputs. Each input supports bipolar and unipolar ranges with 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 4-20mA loops. Appending NTX expansion models can interface up to 64 current inputs on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2230: Ethernet Analog I/O Modules with 8 Differential Voltage Inputs, 2 Discrete I/O

    • 8 differential voltage inputs
    • 2 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2230 modules offer 8 voltage inputs and 2 limit alarms. Each input has true differential 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 0-10V devices. Appending NTX expansion models can interface up to 32 differential voltage inputs on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2240: Ethernet Analog I/O Modules with 16 Single-ended Voltage Inputs

    • 16 single-ended voltage inputs
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2240 modules offer 16 voltage inputs. Each input supports bipolar and unipolar ranges with 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 0-10V devices. Appending NTX expansion models can interface up to 64 voltage inputs on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2310: Ethernet Analog Output Modules with 8 Process Current Outputs

    • 8 process current outputs
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2310 modules offer 8 current outputs. Each output is driven by a 16-bit DAC. NTE Ethernet models provide a compact network interface to control 4-20mA loops. Appending NTX expansion models can interface up to 32 current outputs at a single IP address.
    Select options
  • Compare

    NT2320: Ethernet Analog Output Modules with 8 Process Voltage Outputs

    • 8 process voltage outputs
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2320 modules offer 8 voltage outputs. Each output is driven by a 16-bit DAC. NTE Ethernet models provide a compact network interface to control voltage signal levels. Appending NTX expansion models can interface up to 32 voltage outputs at a single IP address.
    Select options
  • Compare

    XT1210: 8-Channel Differential Analog Current Input Module

    • 0-11mA, 0-20mA, 4-20mA, ±20mA, or 0-20 amps AC Input
    • 8 analog differential current input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1210 offers an isolated Ethernet network interface for up to eight differential current input channels. Differential inputs deliver better measurements and superior noise rejection.
    Select options
  • Compare

    XT1220: 8-Channel Differential Analog Voltage Input Module

    • ±5V, ±10V, 0-5V, 0-10V Input
    • 8 analog differential voltage input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1220 offers an isolated Ethernet network interface for up to eight differential voltage input channels.
    Select options
  • Compare

    XT1230: 16-Channel Single-Ended Analog Current Input Module

    • 0-11mA, 0-20mA, 4-20mA, ±20mA, or 0-20 amps AC Input
    • 16 analog single-ended current input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1230 offers an isolated Ethernet network interface for up to to sixteen single-ended current input channels.
    Select options
  • Compare

    XT1240: 16-Channel Single-ended Analog DC Voltage Input Module

    • Input: ±5V, ±10V, 0-5V, 0-10V
    • 16 analog single-ended voltage input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1240 offers an isolated Ethernet network interface for up to to sixteen single-ended voltage input channels.
    Select options
  • Compare

    XT1530: Analog Output & Digital I/O Ethernet Modules

    • 4 Analog DC Current Outputs
    • 4 Discrete Voltage I/O Channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1530 interfaces analog output and discrete I/O signals between measurement and control devices over Ethernet. Discrete I/O are individually configurable for input or high-side switched output operation.
    Select options
  • Compare

    XT1540: Analog Output & Digital I/O Ethernet Modules

    • 8 Analog DC Voltage Outputs ±10V (calibrated), ±5V (sub-range)
    • 4 Discrete Voltage I/O Channels 0-32V DC
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1540 interfaces analog output and discrete I/O signals between measurement and control devices over Ethernet. Discrete I/O are individually configurable for input or high-side switched output operation.
    Select options
  • Compare

    633T: AC/DC-Powered Signal Splitter

    • Single input, dual output (splitter)
    • 12-36V DC SELV, 90-250V AC
    • Provides two identical outputs from one input signal
    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels. Galvanic isolation eliminates ground loops, reduces noise, and blocks transient signals.
    Select options
  • Compare

    801T: Universal Input Intelligent Temperature Transmitter

    • Thermocouple, RTD, milliVolt, and Resistance Input
    • 0 to 20mA DC, 0 to 10V DC output
    • Limit Alarm
    • 10-36V DC power
    • Software configured
    • Performs linearization, square root extraction, and optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters