Acromag remote I/O modules feature signal conditioners and network I/OÂ for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
TT239: Frequency / Pulse / PWM Input, 12-32V DC Loop Power, 2-Wire Transmitter
Multi-range 0Hz to 100KHz frequency input
Multi-range 0Hz to 3KHz PWM input
4-20mA output (sink/source)
12-32V DC power
The TT239 model is a space-saving two-wire transmitter that isolates and converts a frequency, pulse, or pulse-width modulation (PWM) input to a proportional 4-20mA signal. You can select to measure either the input frequency or the duty cycle. Power is received from the output loop current or a DC supply when using a three-wire connection.
Click here to watch a short AcroMaggie video highlighting the TT230 Series.
TT339: Frequency / Pulse Input, 12-32V DC Local/Bus Power Transmitter
Multi-range 0Hz to 100KHz input
Universal current/voltage output
12-32V DC local/bus power
The TT339 model is a space-saving four-wire transmitter that isolates and converts a frequency or pulse input to a proportional control signal. DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring.
Click here to watch a short video highlighting the TT330 Series.
VPM2000 Series: Loop-Powered Isolator / Alarm with Display
Loop-powered Process Meter
4-20mA input/output
Solid-state relays
Non-incendive, intrinsically safe
These loop-powered 1/8 DIN digital panel meters provide a convenient and informative display of any 4-20mA signal. A dual line display shows the process value on the top line and the units or a tag on the bottom line. Alternatively, you can display the input in one scale on the top line (e.g. height) and another scale on the bottom (e.g. volume).
Click here to watch a short video highlighting the VPM2000 Series.
VPM3000 Series: Universal Transmitter / Alarm with Display
Big, bright display
4-20mA, ±10V, thermocouple, or RTD input
4-20mA, Modbus serial, or alarm relay output options
Acromag VPM3000 Vertuâ„¢ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications.
Learn more about the VPM3000 by watching this short video.
Provides two identical outputs from one input signal
These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels. Galvanic isolation eliminates ground loops, reduces noise, and blocks transient signals.
Acromag’s configuration software is the key to the IntelliPack’s easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
801T: Universal Input Intelligent Temperature Transmitter
Thermocouple, RTD, milliVolt, and Resistance Input
0 to 20mA DC, 0 to 10V DC output
Limit Alarm
10-36V DC power
Software configured
Performs linearization, square root extraction, and optional limit alarm functions
These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
841T: DC Frequency/Pulse Input Intelligent Transmitter
0 to 50KHz, 0 to 65535 pulses input
0 to 20mA DC, 0 to 10V DC output
Mechanical alarm relay (25V @ 5A)
10-36V DC power
Software configured; pulse counter; signal averaging; optional limit alarm functions
These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
924MB: Thermocouple/milliVolt Modbus-RTU Input Module with Limit Alarms
4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt (±100mV DC) input
4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
10 to 36V DC, 24V AC power
Modbus-RTU high-speed RS-485
This signal conditioner is a four-channel analog input module with four discrete outputs. It filters and linearizes thermocouple inputs while providing isolation between input, output, power, and network circuits. Cold junction compensation and upscale/downscale sensor break detection are standard.
951EN, 952EN: Ethernet Analog and Discrete I/O Modules
4 analog inputs
2 analog output
6 discrete I/O channels
Ethernet/IP, Modbus TCP/IP
i2o peer-to-peer available for Modbus TCP/IP only
These modules provide an isolated Ethernet network interface for analog and discrete I/O signals. Multi-range analog inputs and outputs support a wide variety of industrial devices. High-resolution, low noise, A/D and D/A converters deliver high accuracy and reliability.
981PB, 982PB, 983PB: Profibus-DP 12-Channel Digital I/O
Active-Low Inputs, Sinking Outputs
12 input channels, 0 to 35V DC range
12 to 36V DC
High-speed RS-485
These modules provide an isolated Profibus-DP network interface for twelve discrete input and/or output channels. The outputs provide direct on/off, high/low, or open/close control of industrial devices.
APM765 Series: Universal Input with Alarm Panel Meter
Universal input
Isolated 4-20mA and Modbus output options
Push-button or PC programmable,
85-265V AC or 90-265V DC power, optional 12-24V AC or 12-36V DC power
The APM765 displays data collected from process current, DC voltage and temperature inputs. Several output options convert the display into a transmitter with proportional 4-20mA output or a serial communication interface.
NT2510 and NT2530: Ethernet Multi-Function I/O Modules
4 analog inputs
2 analog outputs
4 discrete I/O
Ethernet I/O plus Expansion I/O
Multi-protocol support
NT2510 modules offer 4 current inputs, 2 current outputs, and 4 discrete I/O channels. NT2530 models have voltage input. NTE Ethernet models provide a network interface to monitor and control I/O signals. Appending NTX expansion models can interface up to 24 analog and 16 discrete I/O on a single IP address.
Click here to watch a short video highlighting the features of the BusWorks NT Series.
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.