Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing 1–16 of 24 results

  • Compare

    TT239: Frequency / Pulse / PWM Input, 12-32V DC Loop Power, 2-Wire Transmitter

    • Multi-range 0Hz to 100KHz frequency input
    • Multi-range 0Hz to 3KHz PWM input
    • 4-20mA output (sink/source)
    • 12-32V DC power
    The TT239 model is a space-saving two-wire transmitter that isolates and converts a frequency, pulse, or pulse-width modulation (PWM) input to a proportional 4-20mA signal. You can select to measure either the input frequency or the duty cycle. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.    
    Select options
  • Compare

    TT336: Current/milliVolt Input, DC Power Transmitter

    • Multi-range ±20mA or ±500mV input
    • Universal current/voltage output
    • 12-32V DC power
    DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring. Click here to watch a short video highlighting the TT330 Series.  
    Select options
  • Compare

    TT339: Frequency / Pulse Input, 12-32V DC Local/Bus Power Transmitter

    • Multi-range 0Hz to 100KHz input
    • Universal current/voltage output
    • 12-32V DC local/bus power
    The TT339 model is a space-saving four-wire transmitter that isolates and converts a frequency or pulse input to a proportional control signal. DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring. Click here to watch a short video highlighting the TT330 Series.
    Select options
  • Compare

    VPM3000 Series: Universal Transmitter / Alarm with Display

    • Big, bright display
    • 4-20mA, ±10V, thermocouple, or RTD input
    • 4-20mA, Modbus serial, or alarm relay output options
    Acromag VPM3000 Vertuâ„¢ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications. Learn more about the VPM3000 by watching this short video.
    Select options
  • Compare

    631T, 632T: Single / Dual Channel Isolator

    • 4 to 20mA DC input
    • 4 to 20mA DC output
    • 12-36V DC SELV, 90-250V AC power
    • Single or dual I/O with a dual output model and full isolation
    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels. Galvanic isolation eliminates ground loops, reduces noise, and blocks transient signals.
    Select options
  • Compare

    800C-SIP: IntelliPack Configuration Software

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RJ11 Adapter
    • Interface Cable
    Acromag’s configuration software is the key to the IntelliPack’s easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
    Select options
  • Compare

    841T: DC Frequency/Pulse Input Intelligent Transmitter

    • 0 to 50KHz, 0 to 65535 pulses input
    • 0 to 20mA DC, 0 to 10V DC output
    • Mechanical alarm relay (25V @ 5A)
    • 10-36V DC power
    • Software configured; pulse counter; signal averaging; optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    895M, 896M: DC Input, Frequency Output Math Module

    • 0 to 20mA DC, 0 to 10V DC (selectable ranges), 896M 2 channels input
    • 0 to 10KHz, 0 to 36,000 counts/hr Frequency output, 896M 2 channels
    • Solid-state relay (60V DC @ 500mA) control output
    • 10-36V DC power
    • Software configured, ideal for integrator/totalizer applications, computes arithmetic operations, conditional arguments, track & hold functions
    IntelliPack math modules perform complex mathematical computations and convert DC input signals to scaled DC or frequency outputs.
    Select options
  • Compare

    913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms

    • 4 input channels
    • 0 to 20mA DC (0 to 20A AC with AC sensor) or ±10V DC input range
    • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus RTU high-speed RS-485
    This signal conditioner is a four-channel analog input module with four discrete outputs. It provides isolation between input, output, power, and network circuits.
    Select options
  • Compare

    917MB, 918MB: DC Current/Voltage Modbus-RTU Output Modules with Discrete Outputs

    • 4 analog output channels
    • 0 to 20mA or 0 to 10V DC output range
    • 4 discrete output channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus RTU high-speed RS-485
    These modules drive four analog output channels and also feature four discrete outputs for on/off control. Isolation separates the output, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus RTU protocol.
    Select options
  • Compare

    924MB: Thermocouple/milliVolt Modbus-RTU Input Module with Limit Alarms

    • 4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt (±100mV DC) input
    • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a four-channel analog input module with four discrete outputs. It filters and linearizes thermocouple inputs while providing isolation between input, output, power, and network circuits. Cold junction compensation and upscale/downscale sensor break detection are standard.  
    Select options
  • Compare

    932MB, 934MB: RTD/Resistance Modbus-RTU Input Modules with Limit Alarms or Discrete Outputs

    • 2 or 4 input channels, RTD (100 ohm Pt, 120 ohm Ni, 10 ohm Cu) or resistance (0 to 500 ohms) input
    • Solid-state relays discrete output, Form A, SPST-NO
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a dual or quad-channel analog input module with one discrete/relay output per input channel and a Modbus interface. It filters and linearizes RTD or resistance inputs while providing isolation between input, output, power, and network circuits.
    Select options
  • Compare

    942MB: Frequency/Pulse Counter Modbus-RTU Input Modules with Periodic or Pulse Waveform Input

    • 2 input channels, 0 to 50KHz in 3 selectable ranges: Amplitudes up to 140V AC peak, Amplitudes up to 200V peak, Pulse counter range of 0 to 65535
    • Solid-state discrete output relays (1A DC loads), 0 to 48V DC
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a two-channel analog input module with discrete outputs and Modbus communication. It conditions periodic or pulse waveform inputs and provides solid-state relays for limit alarms or ON/OFF control.
    Select options
  • Compare

    961PB, 962PB: 6-Channel Differential Profibus-DP Input Modules

    • DC Current or DC Voltage Signals
    • 6 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±78mV to ±10V DC with eight range options
    • 12 to 36V DC power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for six analog input channels. Differential inputs eliminate ground loops and thus the need for isolators in any applications.
    Select options
  • Compare

    963PB, 964PB: 12-Channel Single-Ended Input Profibus-DP Modules

    • DC Current or DC Voltage Signals
    • 12 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±1V, ±5V or ±10V DC
    • 12 to 36V DC power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for twelve analog input channels. Compact design saves space and lowers system costs.
    Select options
  • Compare

    965PB: 4 or 6-Channel Thermocouple/mV Input Profibus-DP Modules

    • Thermocouple or Millivolt Signals
    • 4 or 6 input channels, thermocouple or DC millivolts (user-selectable)
    • 12 to 36V DC  power
    • Profibus-DP, RS-485 network up to 12Mbaud
    These modules provide an isolated Profibus-DP network interface for up to six input channels. Differential inputs eliminate ground noise.
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms