Acromag remote I/O modules feature signal conditioners and network I/O for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
Showing all 15 results
-
TT236: Current / milliVolt Input Two-Wire Transmitter
- Multi-range ±20mA or ±500mV input
- 4-20mA ouput (sink/source)
- 12-32 V DC loop/local power
-
VPM3000 Series: Universal Transmitter / Alarm with Display
- Big, bright display
- 4-20mA, ±10V, thermocouple, or RTD input
- 4-20mA, Modbus serial, or alarm relay output options
-
340i: DC-Powered Isolator
- 4 to 20mA DC input
- 4 to 20mA DC output
- 10-36V DC power
- 1500 AC peak isolation prevents ground loops
- Calibration is independent of the load to eliminate load compensation adjustments
-
611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters
- ±100V DC, 0 to 100mA DC, 0 to 20A AC (with optional sensor) input
- 0 to 20mA, 0 to 10V DC output
- 10-36V DC power
- Universal DC I/O transmitters with auto-configuration and self-ranging capabilities
-
800C-SIP: IntelliPack Configuration Software
- Configuration Software
- USB-to-RS232 Adapter
- RS232-to-RJ11 Adapter
- Interface Cable
-
801A Universal TC/RTD/mV Input Intelligent Alarm
- Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), resistance (0 to 500 ohms) input
- Single or dual mechanical relay alarm outputs
- 10-36V DC power
- Software configured
- Multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection)
- On/off controller capability
-
801T: Universal Input Intelligent Temperature Transmitter
- Thermocouple, RTD, milliVolt, and Resistance Input
- 0 to 20mA DC, 0 to 10V DC output
- Limit Alarm
- 10-36V DC power
- Software configured
- Performs linearization, square root extraction, and optional limit alarm functions
-
822A Dual Thermocouple/mV Input Intelligent Alarm
- 2 input channels, thermocouple (types J, K, T, R, S, E, B, N), or millivolt (±100mV DC) input
- Dual mechanical relays output
- 10-36V DC power
- Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
-
913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms
- 4 input channels
- 0 to 20mA DC (0 to 20A AC with AC sensor) or ±10V DC input range
- 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
- 10 to 36V DC, 24V AC power
- Modbus RTU high-speed RS-485
-
917MB, 918MB: DC Current/Voltage Modbus-RTU Output Modules with Discrete Outputs
- 4 analog output channels
- 0 to 20mA or 0 to 10V DC output range
- 4 discrete output channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
- 10 to 36V DC, 24V AC power
- Modbus RTU high-speed RS-485
-
924MB: Thermocouple/milliVolt Modbus-RTU Input Module with Limit Alarms
- 4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt (±100mV DC) input
- 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
932MB, 934MB: RTD/Resistance Modbus-RTU Input Modules with Limit Alarms or Discrete Outputs
- 2 or 4 input channels, RTD (100 ohm Pt, 120 ohm Ni, 10 ohm Cu) or resistance (0 to 500 ohms) input
- Solid-state relays discrete output, Form A, SPST-NO
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
942MB: Frequency/Pulse Counter Modbus-RTU Input Modules with Periodic or Pulse Waveform Input
- 2 input channels, 0 to 50KHz in 3 selectable ranges: Amplitudes up to 140V AC peak, Amplitudes up to 200V peak, Pulse counter range of 0 to 65535
- Solid-state discrete output relays (1A DC loads), 0 to 48V DC
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
TTC-SIP: Software
- Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
- Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
- Easy setup and digital calibration via USB with Windows configuration software.
- Download the configuration software only - from the Software Tab
Signal Conditioning Selection Guide Videos
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.