Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing 1–16 of 20 results

  • Compare

    TT236: Current / milliVolt Input Two-Wire Transmitter

    • Multi-range ±20mA or ±500mV input
    • 4-20mA ouput (sink/source)
    • 12-32 V DC loop/local power
    The TT236 model is a space-saving two-wire transmitter that isolates and converts a DC current or low voltage input to a proportional 4-20mA control signal. A single unit supports both voltage and current input for extra flexibility. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    Select options
  • Compare

    VPM3000 Series: Universal Transmitter / Alarm with Display

    • Big, bright display
    • 4-20mA, ±10V, thermocouple, or RTD input
    • 4-20mA, Modbus serial, or alarm relay output options
    Acromag VPM3000 Vertu™ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications. Learn more about the VPM3000 by watching this short video.
    Select options
  • Compare

    20RM-16-DIN: 19” rack-mount kit with DIN rail

    • 19" rack-mount kit with DIN rail
    Select options
  • Compare

    340i: DC-Powered Isolator

    • 4 to 20mA DC input
    • 4 to 20mA DC output
    • 10-36V DC power
    • 1500 AC peak isolation prevents ground loops
    • Calibration is independent of the load to eliminate load compensation adjustments
    The 340i accepts a process current input and provides an isolated 4 to 20mA process current output signal.
    Select options
  • Compare

    350T NEMA Enclosure

    Mounting Accessories NEMA-4 and MEMA-12 Enclosures
    Read more
  • Compare

    5020-350: Toroidal AC Current Sensor

    • AC Current Sensor to precondition an AC current input signal
    • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
    Select options
  • Compare

    611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters

    • ±100V DC, 0 to 100mA DC, 0 to 20A AC (with optional sensor) input
    • 0 to 20mA, 0 to 10V DC output
    • 10-36V DC power
    • Universal DC I/O transmitters with auto-configuration and self-ranging capabilities
    These units receive DC current or voltage input signals, provide isolation, and output proportional DC current or voltage signals. With support for universal DC I/O ranges, 610T series transmitters provide a solution for a wide variety of isolation and signal conversion tasks.
    Select options
  • Compare

    800C-SIP: IntelliPack Configuration Software

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RJ11 Adapter
    • Interface Cable
    Acromag’s configuration software is the key to the IntelliPack’s easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
    Select options
  • Compare

    801T: Universal Input Intelligent Temperature Transmitter

    • Thermocouple, RTD, milliVolt, and Resistance Input
    • 0 to 20mA DC, 0 to 10V DC output
    • Limit Alarm
    • 10-36V DC power
    • Software configured
    • Performs linearization, square root extraction, and optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    ACC1014: Flat Pack Mounting Kit

    • Surface mount for 250T, 260A and 270i series
    • Snaptrack mount 250T, 260A and 270i series
    Select options
  • Compare

    APM765 Series: Universal Input with Alarm Panel Meter

    • Universal input
    • Isolated 4-20mA and Modbus output options
    • Push-button or PC programmable,
    • 85-265V AC or 90-265V DC power, optional 12-24V AC or 12-36V DC power
    The APM765 displays data collected from process current, DC voltage and temperature inputs. Several output options convert the display into a transmitter with proportional 4-20mA output or a serial communication interface.
    Select options
  • Compare

    DIN Rail: Type T

    • DIN Rail Strip, Type T
    Select options
  • Compare

    EtherStax Mounting Kits

    • EtherStax mounting accessories
    Select options
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
     
    Select options
  • Compare

    ST130 Mounting Accessories

    • Simplifies mounting of ST130 Series transmitters
    • Ideal for mounting in the field or in a control room
    Select options
  • Compare

    ST13C-SIP

    • Configuration software
    • USB isolator
    • Two USB cables
    • One kit recommended per customer
       
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters