Acromag remote I/O modules feature signal conditioners and network I/OÂ for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
Showing all 11 results
-
TT236: Current / milliVolt Input Two-Wire Transmitter
- Multi-range ±20mA or ±500mV input
- 4-20mA ouput (sink/source)
- 12-32 V DC loop/local power
-
340i: DC-Powered Isolator
- 4 to 20mA DC input
- 4 to 20mA DC output
- 10-36V DC power
- 1500 AC peak isolation prevents ground loops
- Calibration is independent of the load to eliminate load compensation adjustments
-
611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters
- ±100V DC, 0 to 100mA DC, 0 to 20A AC (with optional sensor) input
- 0 to 20mA, 0 to 10V DC output
- 10-36V DC power
- Universal DC I/O transmitters with auto-configuration and self-ranging capabilities
-
841T: DC Frequency/Pulse Input Intelligent Transmitter
- 0 to 50KHz, 0 to 65535 pulses input
- 0 to 20mA DC, 0 to 10V DC output
- Mechanical alarm relay (25V @ 5A)
- 10-36V DC power
- Software configured; pulse counter; signal averaging; optional limit alarm functions
-
942MB: Frequency/Pulse Counter Modbus-RTU Input Modules with Periodic or Pulse Waveform Input
- 2 input channels, 0 to 50KHz in 3 selectable ranges: Amplitudes up to 140V AC peak, Amplitudes up to 200V peak, Pulse counter range of 0 to 65535
- Solid-state discrete output relays (1A DC loads), 0 to 48V DC
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
961PB, 962PB: 6-Channel Differential Profibus-DP Input Modules
- DC Current or DC Voltage Signals
- 6 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±78mV to ±10V DC with eight range options
- 12 to 36V DC power
- Profibus-DP, RS-485 network up to 12Mbaud
-
963PB, 964PB: 12-Channel Single-Ended Input Profibus-DP Modules
- DC Current or DC Voltage Signals
- 12 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±1V, ±5V or ±10V DC
- 12 to 36V DC power
- Profibus-DP, RS-485 network up to 12Mbaud
-
965PB: 4 or 6-Channel Thermocouple/mV Input Profibus-DP Modules
- Thermocouple or Millivolt Signals
- 4 or 6 input channels, thermocouple or DC millivolts (user-selectable)
- 12 to 36V DCÂ power
- Profibus-DP, RS-485 network up to 12Mbaud
-
966PB: 4 or 6-Channel RTD/Resistance Input Profibus-DP Modules
- RTD or Resistance Signals
- 4 or 6 input channels, Platinum 100 ohm, Nickel 120 ohm, Copper 10 ohm; 0 to 500 ohms resistance
- 12 to 36V DC power
- Profibus-DP, RS-485 network up to 12Mbaud
-
972PB, 973PB: Analog Output Profibus-DP - RS485 Modules
- 0 to 1mA, 0 to 20mA, or 4 to 20mA DC Current Output; 0 to 1V, 0 to 5V or 0 to 10V DC Output
- 12 to 36V DC Power
- Profibus-DP, RS-485 network up to 12Mbaud
-
4683 Series: RS485-to-RS485 Network Repeater
- Designed for use with Johnson Controls N2 or BACnet MS/TP bus
- 115V AC ±10%, 50/60 Hz, 0.05A or 230V AC ±10%, 50/60 Hz, 0.03A or 24V AC ±10%, 50/60 Hz, 0.18A typical power
- Operating temperature: -25 to 70° C (-13 to 158° F)
Signal Conditioning Selection Guide Videos
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.