Acromag remote I/O modules feature signal conditioners and network I/O for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
Showing all 14 results
-
TT236: Current / milliVolt Input Two-Wire Transmitter
- Multi-range ±20mA or ±500mV input
- 4-20mA ouput (sink/source)
- 12-32 V DC loop/local power
-
TT239: Frequency / Pulse / PWM Input, 12-32V DC Loop Power, 2-Wire Transmitter
- Multi-range 0Hz to 100KHz frequency input
- Multi-range 0Hz to 3KHz PWM input
- 4-20mA output (sink/source)
- 12-32V DC power
-
TT339: Frequency / Pulse Input, 12-32V DC Local/Bus Power Transmitter
- Multi-range 0Hz to 100KHz input
- Universal current/voltage output
- 12-32V DC local/bus power
-
VPM3000 Series: Universal Transmitter / Alarm with Display
- Big, bright display
- 4-20mA, ±10V, thermocouple, or RTD input
- 4-20mA, Modbus serial, or alarm relay output options
-
340i: DC-Powered Isolator
- 4 to 20mA DC input
- 4 to 20mA DC output
- 10-36V DC power
- 1500 AC peak isolation prevents ground loops
- Calibration is independent of the load to eliminate load compensation adjustments
-
611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters
- ±100V DC, 0 to 100mA DC, 0 to 20A AC (with optional sensor) input
- 0 to 20mA, 0 to 10V DC output
- 10-36V DC power
- Universal DC I/O transmitters with auto-configuration and self-ranging capabilities
-
801T: Universal Input Intelligent Temperature Transmitter
- Thermocouple, RTD, milliVolt, and Resistance Input
- 0 to 20mA DC, 0 to 10V DC output
- Limit Alarm
- 10-36V DC power
- Software configured
- Performs linearization, square root extraction, and optional limit alarm functions
-
811A, 812A: Intelligent Alarm; DC Voltage/Current Input
- ±100V or 0 to 22mA DC input ranges or 2 input channels, ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
- Single or dual mechanical relays
- 10-36V DC power
- Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
-
841T: DC Frequency/Pulse Input Intelligent Transmitter
- 0 to 50KHz, 0 to 65535 pulses input
- 0 to 20mA DC, 0 to 10V DC output
- Mechanical alarm relay (25V @ 5A)
- 10-36V DC power
- Software configured; pulse counter; signal averaging; optional limit alarm functions
-
913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms
- 4 input channels
- 0 to 20mA DC (0 to 20A AC with AC sensor) or ±10V DC input range
- 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
- 10 to 36V DC, 24V AC power
- Modbus RTU high-speed RS-485
-
942MB: Frequency/Pulse Counter Modbus-RTU Input Modules with Periodic or Pulse Waveform Input
- 2 input channels, 0 to 50KHz in 3 selectable ranges: Amplitudes up to 140V AC peak, Amplitudes up to 200V peak, Pulse counter range of 0 to 65535
- Solid-state discrete output relays (1A DC loads), 0 to 48V DC
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
250T-FQ, 350T-FQ, 450T-FQ: Frequency Input Loop, DC, or AC-Power Transmitter
- 0 to 25.6KHz frequency input range
- DC voltage or DC current output
- DIN rail G or T mount
-
260A: Limit Alarm; DC Current Input, Loop-Powered
- 4 to 20mA DC input
- Single mechanical relay output
- 4.5V DC from input loop power
- Hi/lo fail-safe option trips alarms above or below set-point
-
361A, 461A: Limit Alarm; DC Voltage/Current Input, AC or DC-Powered
- 0 to 20mA DC, 0 to 100V DC, AC current (with optional sensor) input
- Single or dual mechanical relays output
- 10-36V DC or 115/230V AC power
- 100% adjustable set-point, hi/lo fail-safe operation, jumper-selectable voltage/current input
Signal Conditioning Selection Guide Videos
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.