Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing all 15 results

  • Compare

    TT236: Current / milliVolt Input Two-Wire Transmitter

    • Multi-range ±20mA or ±500mV input
    • 4-20mA ouput (sink/source)
    • 12-32 V DC loop/local power
    The TT236 model is a space-saving two-wire transmitter that isolates and converts a DC current or low voltage input to a proportional 4-20mA control signal. A single unit supports both voltage and current input for extra flexibility. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    Select options
  • Compare

    TT239: Frequency / Pulse / PWM Input, 12-32V DC Loop Power, 2-Wire Transmitter

    • Multi-range 0Hz to 100KHz frequency input
    • Multi-range 0Hz to 3KHz PWM input
    • 4-20mA output (sink/source)
    • 12-32V DC power
    The TT239 model is a space-saving two-wire transmitter that isolates and converts a frequency, pulse, or pulse-width modulation (PWM) input to a proportional 4-20mA signal. You can select to measure either the input frequency or the duty cycle. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.    
    Select options
  • Compare

    TT339: Frequency / Pulse Input, 12-32V DC Local/Bus Power Transmitter

    • Multi-range 0Hz to 100KHz input
    • Universal current/voltage output
    • 12-32V DC local/bus power
    The TT339 model is a space-saving four-wire transmitter that isolates and converts a frequency or pulse input to a proportional control signal. DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring. Click here to watch a short video highlighting the TT330 Series.
    Select options
  • Compare

    VPM3000 Series: Universal Transmitter / Alarm with Display

    • Big, bright display
    • 4-20mA, ±10V, thermocouple, or RTD input
    • 4-20mA, Modbus serial, or alarm relay output options
    Acromag VPM3000 Vertuâ„¢ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications. Learn more about the VPM3000 by watching this short video.
    Select options
  • Compare

    340i: DC-Powered Isolator

    • 4 to 20mA DC input
    • 4 to 20mA DC output
    • 10-36V DC power
    • 1500 AC peak isolation prevents ground loops
    • Calibration is independent of the load to eliminate load compensation adjustments
    The 340i accepts a process current input and provides an isolated 4 to 20mA process current output signal.
    Select options
  • Compare

    611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters

    • ±100V DC, 0 to 100mA DC, 0 to 20A AC (with optional sensor) input
    • 0 to 20mA, 0 to 10V DC output
    • 10-36V DC power
    • Universal DC I/O transmitters with auto-configuration and self-ranging capabilities
    These units receive DC current or voltage input signals, provide isolation, and output proportional DC current or voltage signals. With support for universal DC I/O ranges, 610T series transmitters provide a solution for a wide variety of isolation and signal conversion tasks.
    Select options
  • Compare

    801T: Universal Input Intelligent Temperature Transmitter

    • Thermocouple, RTD, milliVolt, and Resistance Input
    • 0 to 20mA DC, 0 to 10V DC output
    • Limit Alarm
    • 10-36V DC power
    • Software configured
    • Performs linearization, square root extraction, and optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    811A, 812A: Intelligent Alarm; DC Voltage/Current Input

    • ±100V or 0 to 22mA DC input ranges or 2 input channels, ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
    • Single or dual mechanical relays
    • 10-36V DC power
    • Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
    IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.  
    Select options
  • Compare

    841T: DC Frequency/Pulse Input Intelligent Transmitter

    • 0 to 50KHz, 0 to 65535 pulses input
    • 0 to 20mA DC, 0 to 10V DC output
    • Mechanical alarm relay (25V @ 5A)
    • 10-36V DC power
    • Software configured; pulse counter; signal averaging; optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms

    • 4 input channels
    • 0 to 20mA DC (0 to 20A AC with AC sensor) or ±10V DC input range
    • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus RTU high-speed RS-485
    This signal conditioner is a four-channel analog input module with four discrete outputs. It provides isolation between input, output, power, and network circuits.
    Select options
  • Compare

    951EN, 952EN: Ethernet Analog and Discrete I/O Modules

    • 4 analog inputs
    • 2 analog output
    • 6 discrete I/O channels
    • Ethernet/IP, Modbus TCP/IP
    • i2o peer-to-peer available for Modbus TCP/IP only
    These modules provide an isolated Ethernet network interface for analog and discrete I/O signals. Multi-range analog inputs and outputs support a wide variety of industrial devices. High-resolution, low noise, A/D and D/A converters deliver high accuracy and reliability.
    Select options
  • Compare

    NT2510 and NT2530: Ethernet Multi-Function I/O Modules

    • 4 analog inputs
    • 2 analog outputs
    • 4 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2510 modules offer 4 current inputs, 2 current outputs, and 4 discrete I/O channels. NT2530 models have voltage input. NTE Ethernet models provide a network interface to monitor and control I/O signals. Appending NTX expansion models can interface up to 24 analog and 16 discrete I/O on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    250T-FQ, 350T-FQ, 450T-FQ: Frequency Input Loop, DC, or AC-Power Transmitter

    • 0 to 25.6KHz frequency input range
    • DC voltage or DC current output
    • DIN rail G or T mount
    These transmitters accept periodic or pulse waveform signals such as those originating from tachometers, magnetic transducers, and turbine flow meters, and provide a proportional process current or voltage output signal.    
    Select options
  • Compare

    260A: Limit Alarm; DC Current Input, Loop-Powered

    • 4 to 20mA DC input
    • Single mechanical relay output
    • 4.5V DC from input loop power
    • Hi/lo fail-safe option trips alarms above or below set-point
    The 260A accepts a 4 to 20mA input signal and provides a dry contact relay output if the input exceeds a user-defined set-point limit. Power is received from the input loop.        
    Select options
  • Compare

    361A, 461A: Limit Alarm; DC Voltage/Current Input, AC or DC-Powered

    • 0 to 20mA DC, 0 to 100V DC, AC current (with optional sensor) input
    • Single or dual mechanical relays output
    • 10-36V DC or 115/230V AC power
    • 100% adjustable set-point, hi/lo fail-safe operation, jumper-selectable voltage/current input
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms