Acromag remote I/O modules feature signal conditioners and network I/OÂ for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
Showing 1–16 of 24 results
-
TT236: Current / milliVolt Input Two-Wire Transmitter
- Multi-range ±20mA or ±500mV input
- 4-20mA ouput (sink/source)
- 12-32 V DC loop/local power
-
TT239: Frequency / Pulse / PWM Input, 12-32V DC Loop Power, 2-Wire Transmitter
- Multi-range 0Hz to 100KHz frequency input
- Multi-range 0Hz to 3KHz PWM input
- 4-20mA output (sink/source)
- 12-32V DC power
-
TT336: Current/milliVolt Input, DC Power Transmitter
- Multi-range ±20mA or ±500mV input
- Universal current/voltage output
- 12-32V DC power
-
TT339: Frequency / Pulse Input, 12-32V DC Local/Bus Power Transmitter
- Multi-range 0Hz to 100KHz input
- Universal current/voltage output
- 12-32V DC local/bus power
-
DT236: Current / milliVolt Input Two-Wire Dual Transmitter
- Â Dual channels
-  ±20mA, ±500mV inputs
- 4-20mA outputs (sink/source)
- 7-32V DC loop power
-
DT336: Current / milliVolt Input Four-Wire Dual Transmitter
- Dual channels
- ±20mA, ±500mV inputs
- 0-20mA, ±10V outputs
- 6-32V DC local/bus power
Click here to watch a short video highlighting the features of the DT336.
-
340i: DC-Powered Isolator
- 4 to 20mA DC input
- 4 to 20mA DC output
- 10-36V DC power
- 1500 AC peak isolation prevents ground loops
- Calibration is independent of the load to eliminate load compensation adjustments
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters
- ±100V DC, 0 to 100mA DC, 0 to 20A AC (with optional sensor) input
- 0 to 20mA, 0 to 10V DC output
- 10-36V DC power
- Universal DC I/O transmitters with auto-configuration and self-ranging capabilities
-
800C-SIP: IntelliPack Configuration Software
- Configuration Software
- USB-to-RS232 Adapter
- RS232-to-RJ11 Adapter
- Interface Cable
-
811T: DC Voltage/Current Input Intelligent Transmitter
- ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
- 0 to 20mA DC, 0 to 10V DC output
- Mechanical relay alarm (25V @ 5A)
- 10-36V DC power
- Software configured, performs linearization, square root extraction, and optional limit alarm functions
-
841T: DC Frequency/Pulse Input Intelligent Transmitter
- 0 to 50KHz, 0 to 65535 pulses input
- 0 to 20mA DC, 0 to 10V DC output
- Mechanical alarm relay (25V @ 5A)
- 10-36V DC power
- Software configured; pulse counter; signal averaging; optional limit alarm functions
-
961PB, 962PB: 6-Channel Differential Profibus-DP Input Modules
- DC Current or DC Voltage Signals
- 6 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±78mV to ±10V DC with eight range options
- 12 to 36V DC power
- Profibus-DP, RS-485 network up to 12Mbaud
-
963PB, 964PB: 12-Channel Single-Ended Input Profibus-DP Modules
- DC Current or DC Voltage Signals
- 12 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±1V, ±5V or ±10V DC
- 12 to 36V DC power
- Profibus-DP, RS-485 network up to 12Mbaud
-
965PB: 4 or 6-Channel Thermocouple/mV Input Profibus-DP Modules
- Thermocouple or Millivolt Signals
- 4 or 6 input channels, thermocouple or DC millivolts (user-selectable)
- 12 to 36V DCÂ power
- Profibus-DP, RS-485 network up to 12Mbaud
-
966PB: 4 or 6-Channel RTD/Resistance Input Profibus-DP Modules
- RTD or Resistance Signals
- 4 or 6 input channels, Platinum 100 ohm, Nickel 120 ohm, Copper 10 ohm; 0 to 500 ohms resistance
- 12 to 36V DC power
- Profibus-DP, RS-485 network up to 12Mbaud
Signal Conditioning Selection Guide Videos
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.