Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing 1–16 of 17 results

  • Compare

    5020-350: Toroidal AC Current Sensor

    • AC Current Sensor to precondition an AC current input signal
    • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
    Select options
  • Compare

    5034-186: Configuration Software CD-ROM

    • Configuration software CD
    Acromag’s configuration software is the key to the I/O modules’ easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
    Select options
  • Compare

    800C-SIP: IntelliPack Configuration Software

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RJ11 Adapter
    • Interface Cable
    Acromag’s configuration software is the key to the IntelliPack’s easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
    Select options
  • Compare

    900C-SIP: Configuration Software Interface Package

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RS485 Adapter
    • Interface Cable
     
    Select options
  • Compare

    Agilityâ„¢ Config Tool (Tethered)

    • Tethered Agilityâ„¢ Config Tool mobile application
    • For Acromag SP Series Signal Splitters and most TT Series Transmitters
    • Download available on Google Play for free.
    • Download Windows configuration software from the software tab below.
    Read more
  • Compare

    AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O

    • Modbus/TCP or Modbus/RTU
    • These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
    • Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
    Select options
  • Compare

    Digital Display Panel Meter Accessories

    • Plastic enclosure
    • Pipe-mount kit
    • Cables
    • Adapters
    Select from a variety of of panel meter accessories.  
    Select options
  • Compare

    Profibus-DP GSD Files

    • Download GSD files from the Software Tab
    Read more
  • Compare

    SP233: Two-Wire Thermocouple / milliVolt Input Signal Splitter

    • Universal thermocouple or ±100mV input
    • 4-20mA outputs (sink/source)
    • 7-32V DC Loop/local power
    The SP233 model is a high-performance signal splitter that converts one millivolt or thermocouple sensor input into two proportional isolated 4-20mA control signals. Power is received from one or both output loop currents. Click here to watch a short video highlighting the features of the Acromag SP Series.
    Select options
  • Compare

    SP236: Two-Wire Current / milliVolt Input Signal Splitter

    • DC current and low voltage input
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop power
    The SP236 model is a high-performance signal splitter that converts one DC current or millivolt input into two isolated proportional 4-20mA control signals. Power is received from one or both output loop currents. Click here to watch a short video highlighting the features of the Acromag SP Series.
    Select options
  • Compare

    SP237: Two-Wire Process Voltage Input Signal Splitter

    • Multi-range ±1V, ±5V, or ±10V input
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop power
    The SP237 model is a high-performance signal splitter that converts one process-level DC voltage input into two proportional isolated 4-20mA control signals. Power is received from one or both output loop currents. Click here to watch a short video highlighting the features of the Acromag SP Series.
    Select options
  • Compare

    SP238: Two-Wire High Voltage Input Signal Splitter

    • Multi-range ±15V, ±75V, or ±150V input
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop/local power
    The SP238 model is a high-performance signal splitter that converts one high-level DC voltage input into two proportional isolated 4-20mA control signals. power is received from one or both output loop currents. Click here to watch a short video highlighting the features of the Acromag SP Series.
    Select options
  • Compare

    Terminal Block Replacements

    • Simplifies wiring connections on Acromag I/O Modules
    • Barrier strip or spring clamp terminal block kits
    • Provide safe and secure wiring connections
    Select options
  • Compare

    TT234: Potentiometer / Thermistor Input, Two-Wire Transmitter

    • Potentometer / slidewire, thermister input
    • 4 to 20mA output (sink / source)
    • 12-32V DC loop / local power
    • USB configuration
    The TT234 model is a space-saving two-wire transmitter that isolates and converts a resistive sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    Select options
  • Compare

    TTC-SIP: Software

    • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
    • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
    • Easy setup and digital calibration via USB with Windows configuration software.
    • Download the configuration software only - from the Software Tab
    Select options
  • Compare

    XT-SIP: Software Interface Package

    • Software Interface Package for BusWorks XT Series Ethernet I/O modules.
    • Easy setup and digital calibration via USB with Windows configuration software
    • Download software only from the Software Tab below
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms