Acromag remote I/O modules feature signal conditioners and network I/OÂ for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
Showing all 15 results
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
801T: Universal Input Intelligent Temperature Transmitter
- Thermocouple, RTD, milliVolt, and Resistance Input
- 0 to 20mA DC, 0 to 10V DC output
- Limit Alarm
- 10-36V DC power
- Software configured
- Performs linearization, square root extraction, and optional limit alarm functions
-
901MB, 902MB, 903MB: Multi-Channel Modbus-RTU Discrete I/O Modules
- Active-Low Inputs, Sinking Outputs (Low-Side Switching)
- 12 input and/or 12 output channels
- 0 to 35V DC I/O range
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
904MB, 905MB, 906MB: Multi-Channel Discrete I/O Modules
- Active-High Inputs, Sourcing Outputs (High-Side Switching)
- 12 input and/or 12 output channels
- 0 to 35V DC I/O range
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
951EN, 952EN: Ethernet Analog and Discrete I/O Modules
- 4 analog inputs
- 2 analog output
- 6 discrete I/O channels
- Ethernet/IP, Modbus TCP/IP
- i2o peer-to-peer available for Modbus TCP/IP only
-
NT2510 and NT2530: Ethernet Multi-Function I/O Modules
- 4 analog inputs
- 2 analog outputs
- 4 discrete I/O
- Ethernet I/O plus Expansion I/O
- Multi-protocol support
-
SP233: Two-Wire Thermocouple / milliVolt Input Signal Splitter
- Universal thermocouple or ±100mV input
- 4-20mA outputs (sink/source)
- 7-32V DC Loop/local power
-
SP236: Two-Wire Current / milliVolt Input Signal Splitter
- DC current and low voltage input
- 4-20mA outputs (sink/source)
- 7-32V DC loop power
-
SP237: Two-Wire Process Voltage Input Signal Splitter
- Multi-range ±1V, ±5V, or ±10V input
- 4-20mA outputs (sink/source)
- 7-32V DC loop power
-
SP238: Two-Wire High Voltage Input Signal Splitter
- Multi-range ±15V, ±75V, or ±150V input
- 4-20mA outputs (sink/source)
- 7-32V DC loop/local power
-
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
-
XTA-120V-6: Solid-State Relay Input Modules
- 6 optocoupler channels
- 120V AC/DC input with optical isolation
- Universal 5/12/24V logic output
-
XTA-MRNO-6: Mechanical Relay Output Modules
- 6 digital I/O channels
- Â Universal 5/12/24V logic inputs
- Â Form A, 250V AC / 30V DC @ 5A relay outputs
-
653T: Loop-Powered Single Input, Dual Output Signal Splitter
- One 4 to 20mA DC input
- Two 4 to 20mA DC outputs
- 12-50V DC power from output loop
- Signal splitter provides two identical outputs from one input signal
Signal Conditioning Selection Guide Videos
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.