Acromag remote I/O modules feature signal conditioners and network I/OÂ for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
Showing 1–16 of 20 results
-
TT239: Frequency / Pulse / PWM Input, 12-32V DC Loop Power, 2-Wire Transmitter
- Multi-range 0Hz to 100KHz frequency input
- Multi-range 0Hz to 3KHz PWM input
- 4-20mA output (sink/source)
- 12-32V DC power
-
TT339: Frequency / Pulse Input, 12-32V DC Local/Bus Power Transmitter
- Multi-range 0Hz to 100KHz input
- Universal current/voltage output
- 12-32V DC local/bus power
-
NT2610: Ethernet Thermocouple milliVolt Input Modules with Discrete I/O
- 8 thermocouple / mV inputs
- 2 discrete I/O
- Ethernet I/O plus Expansion I/O
- Multi-protocol support
-
NT2620: Ethernet RTD/Resistance Input Modules with Discrete I/O
- 4 RTD/resistance inputs
- 2 discrete I/O
- Ethernet I/O plus Expansion I/O
- Multi-protocol support
-
4001 Serial Cables
5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection -
4001-095: USB-to-Serial Adapter
- USB-to-serial adapter
- Easy to use to setup and re-configure modules
-
5030 Cable Series
- 5030-902: IntelliPack Cable
- 5030-913: IntelliPack Serial Port Adapter
-
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
-
841T: DC Frequency/Pulse Input Intelligent Transmitter
- 0 to 50KHz, 0 to 65535 pulses input
- 0 to 20mA DC, 0 to 10V DC output
- Mechanical alarm relay (25V @ 5A)
- 10-36V DC power
- Software configured; pulse counter; signal averaging; optional limit alarm functions
-
965EN: Ethernet Thermocouple milliVolt Input Modules
- 4 or 6-channel thermocouple/milliVolt input
- Ethernet/IP, Modbus TCP/IP
- i2o peer-to-peer available for Modbus TCP/IP 6-channel only
-
966EN: Ethernet RTD Resistance Input Modules
- 4 or 6-channel RTD/resistance input
- Ethernet/IP, Modbus TCP/IP
- i2o peer-to-peer available for Modbus TCP/IP 6-channel only
-
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
-
SP233: Two-Wire Thermocouple / milliVolt Input Signal Splitter
- Universal thermocouple or ±100mV input
- 4-20mA outputs (sink/source)
- 7-32V DC Loop/local power
-
SP236: Two-Wire Current / milliVolt Input Signal Splitter
- DC current and low voltage input
- 4-20mA outputs (sink/source)
- 7-32V DC loop power
-
SP237: Two-Wire Process Voltage Input Signal Splitter
- Multi-range ±1V, ±5V, or ±10V input
- 4-20mA outputs (sink/source)
- 7-32V DC loop power
-
SP238: Two-Wire High Voltage Input Signal Splitter
- Multi-range ±15V, ±75V, or ±150V input
- 4-20mA outputs (sink/source)
- 7-32V DC loop/local power
Signal Conditioning Selection Guide Videos
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.