Acromag remote I/O modules feature signal conditioners and network I/OÂ for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
Showing all 12 results
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
811A, 812A: Intelligent Alarm; DC Voltage/Current Input
- ±100V or 0 to 22mA DC input ranges or 2 input channels, ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
- Single or dual mechanical relays
- 10-36V DC power
- Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
-
913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms
- 4 input channels
- 0 to 20mA DC (0 to 20A AC with AC sensor) or ±10V DC input range
- 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
- 10 to 36V DC, 24V AC power
- Modbus RTU high-speed RS-485
-
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
-
SP233: Two-Wire Thermocouple / milliVolt Input Signal Splitter
- Universal thermocouple or ±100mV input
- 4-20mA outputs (sink/source)
- 7-32V DC Loop/local power
-
SP236: Two-Wire Current / milliVolt Input Signal Splitter
- DC current and low voltage input
- 4-20mA outputs (sink/source)
- 7-32V DC loop power
-
SP237: Two-Wire Process Voltage Input Signal Splitter
- Multi-range ±1V, ±5V, or ±10V input
- 4-20mA outputs (sink/source)
- 7-32V DC loop power
-
SP238: Two-Wire High Voltage Input Signal Splitter
- Multi-range ±15V, ±75V, or ±150V input
- 4-20mA outputs (sink/source)
- 7-32V DC loop/local power
-
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
-
653T: Loop-Powered Single Input, Dual Output Signal Splitter
- One 4 to 20mA DC input
- Two 4 to 20mA DC outputs
- 12-50V DC power from output loop
- Signal splitter provides two identical outputs from one input signal
-
4683 Series: RS485-to-RS485 Network Repeater
- Designed for use with Johnson Controls N2 or BACnet MS/TP bus
- 115V AC ±10%, 50/60 Hz, 0.05A or 230V AC ±10%, 50/60 Hz, 0.03A or 24V AC ±10%, 50/60 Hz, 0.18A typical power
- Operating temperature: -25 to 70° C (-13 to 158° F)
-
361A, 461A: Limit Alarm; DC Voltage/Current Input, AC or DC-Powered
- 0 to 20mA DC, 0 to 100V DC, AC current (with optional sensor) input
- Single or dual mechanical relays output
- 10-36V DC or 115/230V AC power
- 100% adjustable set-point, hi/lo fail-safe operation, jumper-selectable voltage/current input
Signal Conditioning Selection Guide Videos
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.