Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing 1–16 of 23 results

  • Compare

    TT336: Current/milliVolt Input, DC Power Transmitter

    • Multi-range ±20mA or ±500mV input
    • Universal current/voltage output
    • 12-32V DC power
    DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring. Click here to watch a short video highlighting the TT330 Series.  
    Select options
  • Compare

    DT235: RTD / Resistance Input Two-Wire Dual Transmitter

    • Dual channels
    • RTD (Pt, Ni, Cu), 0-4500 ohm inputs
    • 4-20mA output (sink/source)
    • 7-32V DC loop power
    The DT235 model is a two-wire dual transmitter that isolates and converts RTD or linear resistance sensor inputs to a proportional 4-20mA control signal.

    Click here to watch a short video highlighting the features of the DT235.

    Select options
  • Compare

    DT335: RTD / Resistance Input Four-wire Dual Transmitter

    • Dual channels
    • RTD (Pt, Ni, Cu) or 0-4500 ohm input
    • 0-20mA, ±10V outputs
    • 6-32V DC local/bus power
    The DT335 model is a four-wire dual transmitter that isolates and converts RTD or linear resistance sensor inputs to proportional control signals. Click here to watch a short video highlighting the features of the DT335.
    Select options
  • Compare

    TT231: RTD / Resistance Input Two-Wire Transmitter

    • 100 ohm Pt RTD or 0-900 ohm input
    • 4-20mA output (sink/source)
    • 12-32V DC loop/local power
    • USB configuration
    The TT231 model is a space-saving two-wire transmitter that converts a 100 ohm Platinum RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    Select options
  • Compare

    VPM3000 Series: Universal Transmitter / Alarm with Display

    • Big, bright display
    • 4-20mA, ±10V, thermocouple, or RTD input
    • 4-20mA, Modbus serial, or alarm relay output options
    Acromag VPM3000 Vertuâ„¢ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications. Learn more about the VPM3000 by watching this short video.
    Select options
  • Compare

    631T, 632T: Single / Dual Channel Isolator

    • 4 to 20mA DC input
    • 4 to 20mA DC output
    • 12-36V DC SELV, 90-250V AC power
    • Single or dual I/O with a dual output model and full isolation
    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels. Galvanic isolation eliminates ground loops, reduces noise, and blocks transient signals.
    Select options
  • Compare

    657T, 658T: Single or Dual Channel, RTD Input, Loop-powered Transmitter

    • 100 ohm Pt, 120 ohm Ni, 10 ohm Cu (selectable type) input
    • 4 to 20mA DC output
    • 12-50V DC from output loop power
    • DIP-switch configuration, push-button calibration
    These units accept universal RTD or resistance input signals and output proportional DC current signals. The output can also be linearized to the input sensor signal.
    Select options
  • Compare

    801T: Universal Input Intelligent Temperature Transmitter

    • Thermocouple, RTD, milliVolt, and Resistance Input
    • 0 to 20mA DC, 0 to 10V DC output
    • Limit Alarm
    • 10-36V DC power
    • Software configured
    • Performs linearization, square root extraction, and optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options
  • Compare

    ESW-MBLIB: Ethernet Modbus C Library Software

    • Universal support for five operating systems
    • C source code provided
    • Demo program included
    Select options
  • Compare

    SP233: Two-Wire Thermocouple / milliVolt Input Signal Splitter

    • Universal thermocouple or ±100mV input
    • 4-20mA outputs (sink/source)
    • 7-32V DC Loop/local power
    The SP233 model is a high-performance signal splitter that converts one millivolt or thermocouple sensor input into two proportional isolated 4-20mA control signals. Power is received from one or both output loop currents. Click here to watch a short video highlighting the features of the Acromag SP Series.
    Select options
  • Compare

    SP236: Two-Wire Current / milliVolt Input Signal Splitter

    • DC current and low voltage input
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop power
    The SP236 model is a high-performance signal splitter that converts one DC current or millivolt input into two isolated proportional 4-20mA control signals. Power is received from one or both output loop currents. Click here to watch a short video highlighting the features of the Acromag SP Series.
    Select options
  • Compare

    SP237: Two-Wire Process Voltage Input Signal Splitter

    • Multi-range ±1V, ±5V, or ±10V input
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop power
    The SP237 model is a high-performance signal splitter that converts one process-level DC voltage input into two proportional isolated 4-20mA control signals. Power is received from one or both output loop currents. Click here to watch a short video highlighting the features of the Acromag SP Series.
    Select options
  • Compare

    SP238: Two-Wire High Voltage Input Signal Splitter

    • Multi-range ±15V, ±75V, or ±150V input
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop/local power
    The SP238 model is a high-performance signal splitter that converts one high-level DC voltage input into two proportional isolated 4-20mA control signals. power is received from one or both output loop currents. Click here to watch a short video highlighting the features of the Acromag SP Series.
    Select options
  • Compare

    ST131: Transmitter, RTD Input, Loop-Powered

    • 100 ohm Pt RTD or 0-900 ohm input
    • 4 to 20mA DC output
    • 9-32V DC from output loop power
    • USB-configured
    The ST131 is a low-cost two-wire transmitter that converts a 100 ohm Platinum RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current.
    Select options
  • Compare

    TT234: Potentiometer / Thermistor Input, Two-Wire Transmitter

    • Potentometer / slidewire, thermister input
    • 4 to 20mA output (sink / source)
    • 12-32V DC loop / local power
    • USB configuration
    The TT234 model is a space-saving two-wire transmitter that isolates and converts a resistive sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    Select options
  • Compare

    TT235: Isolated RTD Input, Loop Power, 2-Wire Transmitter

    • Selectable RTD or linear resistance input type or 0-500 ohm input
    • 4-20mA output (sink/source)
    • 12-32V DC loop/local power
    • USB configuration
    The TT235 model is a space-saving two-wire transmitter that isolates and converts an RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms