Acromag remote I/O modules feature signal conditioners and network I/OÂ for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
Showing 1–16 of 27 results
-
DT233: Thermocouple / milliVolt Input Two-Wire Dual Transmitter
- Dual channels
- Universal thermocouple, mV input
- 4-20mA outputs (sink/source)
- 7-32V DC loop/local
Click here to watch a short video highlighting the features of the DT233.
-
DT333: Thermocouple / milliVolt Input Four-Wire Dual Transmitter
- Dual channels
- Universal thermocouple, mV inputs
- Isolated current or voltage outputs
- 6-32V DC local/bus power
-
TT233: Thermocouple / milliVolt Input Two-Wire Transmitter
- Universal TC type J, K, T, R, S, E, B, N or ±100mV input
- 4-20mA ouput (sink/source)
- 12-32 V DC loop/local power
-
TT333: Thermocouple / milliVolt Input Four-wire Transmitter
- Universal thermocouple / millivolt input
- Universal current / voltage output
- 12-32V DC local / bus power
-
TT336: Current/milliVolt Input, DC Power Transmitter
- Multi-range ±20mA or ±500mV input
- Universal current/voltage output
- 12-32V DC power
-
VPM3000 Series: Universal Transmitter / Alarm with Display
- Big, bright display
- 4-20mA, ±10V, thermocouple, or RTD input
- 4-20mA, Modbus serial, or alarm relay output options
-
631T, 632T: Single / Dual Channel Isolator
- 4 to 20mA DC input
- 4 to 20mA DC output
- 12-36V DC SELV, 90-250V AC power
- Single or dual I/O with a dual output model and full isolation
-
655T, 656T: Single or Dual Channel, Thermocouple/milliVolt Input, Loop-powered Transmitter
- TC (types J, K T, R, S, E, B, N), ±1V DC, selectable range/type input
- 4 to 20mA DC output
- 12-50V DC from output loop power
- DIP-switch configuration, signal linearizer, push-button calibration
-
801T: Universal Input Intelligent Temperature Transmitter
- Thermocouple, RTD, milliVolt, and Resistance Input
- 0 to 20mA DC, 0 to 10V DC output
- Limit Alarm
- 10-36V DC power
- Software configured
- Performs linearization, square root extraction, and optional limit alarm functions
-
961PB, 962PB: 6-Channel Differential Profibus-DP Input Modules
- DC Current or DC Voltage Signals
- 6 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±78mV to ±10V DC with eight range options
- 12 to 36V DC power
- Profibus-DP, RS-485 network up to 12Mbaud
-
963PB, 964PB: 12-Channel Single-Ended Input Profibus-DP Modules
- DC Current or DC Voltage Signals
- 12 input channels, 0 to 20mA in 3 selectable ranges (0 to 20 amps AC with optinal AC sensor) or ±1V, ±5V or ±10V DC
- 12 to 36V DC power
- Profibus-DP, RS-485 network up to 12Mbaud
-
965PB: 4 or 6-Channel Thermocouple/mV Input Profibus-DP Modules
- Thermocouple or Millivolt Signals
- 4 or 6 input channels, thermocouple or DC millivolts (user-selectable)
- 12 to 36V DCÂ power
- Profibus-DP, RS-485 network up to 12Mbaud
-
966PB: 4 or 6-Channel RTD/Resistance Input Profibus-DP Modules
- RTD or Resistance Signals
- 4 or 6 input channels, Platinum 100 ohm, Nickel 120 ohm, Copper 10 ohm; 0 to 500 ohms resistance
- 12 to 36V DC power
- Profibus-DP, RS-485 network up to 12Mbaud
-
972PB, 973PB: Analog Output Profibus-DP - RS485 Modules
- 0 to 1mA, 0 to 20mA, or 4 to 20mA DC Current Output; 0 to 1V, 0 to 5V or 0 to 10V DC Output
- 12 to 36V DC Power
- Profibus-DP, RS-485 network up to 12Mbaud
-
ESW-MBLIB: Ethernet Modbus C Library Software
- Universal support for five operating systems
- C source code provided
- Demo program included
-
SP233: Two-Wire Thermocouple / milliVolt Input Signal Splitter
- Universal thermocouple or ±100mV input
- 4-20mA outputs (sink/source)
- 7-32V DC Loop/local power
Signal Conditioning Selection Guide Videos
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.