Acromag remote I/O modules feature signal conditioners and network I/OÂ for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
TT236: Current / milliVolt Input Two-Wire Transmitter
Multi-range ±20mA or ±500mV input
4-20mA ouput (sink/source)
12-32 V DC loop/local power
The TT236 model is a space-saving two-wire transmitter that isolates and converts a DC current or low voltage input to a proportional 4-20mA control signal. A single unit supports both voltage and current input for extra flexibility. Power is received from the output loop current or a DC supply when using a three-wire connection.
Click here to watch a short AcroMaggie video highlighting the TT230 Series.
DT236: Current / milliVolt Input Two-Wire Dual Transmitter
 Dual channels
 ±20mA, ±500mV inputs
4-20mA outputs (sink/source)
7-32V DC loop power
The DT236 model is a dual two-wire transmitter that isolates and converts DC current or low voltage inputs to proportional 4-20mA control signals. Power is received from the output loop current or a DC supply when using a three-wire connection.
Click here to watch a short video highlighting the features of the DT236.
VPM2000 Series: Loop-Powered Isolator / Alarm with Display
Loop-powered Process Meter
4-20mA input/output
Solid-state relays
Non-incendive, intrinsically safe
These loop-powered 1/8 DIN digital panel meters provide a convenient and informative display of any 4-20mA signal. A dual line display shows the process value on the top line and the units or a tag on the bottom line. Alternatively, you can display the input in one scale on the top line (e.g. height) and another scale on the bottom (e.g. volume).
Click here to watch a short video highlighting the VPM2000 Series.
VPM3000 Series: Universal Transmitter / Alarm with Display
Big, bright display
4-20mA, ±10V, thermocouple, or RTD input
4-20mA, Modbus serial, or alarm relay output options
Acromag VPM3000 Vertuâ„¢ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications.
Learn more about the VPM3000 by watching this short video.
These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels.
These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Power is derived from the input signal current. Each channel operates independently and is isolated from the others to prevent interaction between channels.
Acromag’s configuration software is the key to the IntelliPack’s easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
801T: Universal Input Intelligent Temperature Transmitter
Thermocouple, RTD, milliVolt, and Resistance Input
0 to 20mA DC, 0 to 10V DC output
Limit Alarm
10-36V DC power
Software configured
Performs linearization, square root extraction, and optional limit alarm functions
These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
APM765 Series: Universal Input with Alarm Panel Meter
Universal input
Isolated 4-20mA and Modbus output options
Push-button or PC programmable,
85-265V AC or 90-265V DC power, optional 12-24V AC or 12-36V DC power
The APM765 displays data collected from process current, DC voltage and temperature inputs. Several output options convert the display into a transmitter with proportional 4-20mA output or a serial communication interface.
The TT351 model is a space-saving four-wire transmitter that converts a four or six wire strain gauge bridge or load cell or milliVolt sensor signal to an isolated voltage or current output signal.
Click here to watch a short video highlighting the TT351 features.
The 270i accepts a process current input and provides an isolated 4 to 20mA process current output signal. Power is received from the input signal current.
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.