Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing all 11 results

  • Compare

    TT236: Current / milliVolt Input Two-Wire Transmitter

    • Multi-range ±20mA or ±500mV input
    • 4-20mA ouput (sink/source)
    • 12-32 V DC loop/local power
    The TT236 model is a space-saving two-wire transmitter that isolates and converts a DC current or low voltage input to a proportional 4-20mA control signal. A single unit supports both voltage and current input for extra flexibility. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    Select options
  • Compare

    DT236: Current / milliVolt Input Two-Wire Dual Transmitter

    •  Dual channels
    •  ±20mA, ±500mV inputs
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop power
    The DT236 model is a dual two-wire transmitter that isolates and converts DC current or low voltage inputs to proportional 4-20mA control signals. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short video highlighting the features of the DT236.  
    Select options
  • Compare

    VPM2000 Series: Loop-Powered Isolator / Alarm with Display

    • Loop-powered Process Meter
    • 4-20mA input/output
    • Solid-state relays
    • Non-incendive, intrinsically safe
    These loop-powered 1/8 DIN digital panel meters provide a convenient and informative display of any 4-20mA signal. A dual line display shows the process value on the top line and the units or a tag on the bottom line. Alternatively, you can display the input in one scale on the top line (e.g. height) and another scale on the bottom (e.g. volume). Click here to watch a short video highlighting the VPM2000 Series.
    Select options
  • Compare

    5020-350: Toroidal AC Current Sensor

    • AC Current Sensor to precondition an AC current input signal
    • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
    Select options
  • Compare

    651T, 652T: Multi-Channel, Two-Wire Isolators

    • DC current input
    • Single/dual-channel DC-powered isolators
    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels.
    Select options
  • Compare

    671T, 672T, 674T: Multi-Channel, Two-Wire Isolators

    • DC current input
    • Single, dual, or quad I/O loop-powered isolators
    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Power is derived from the input signal current. Each channel operates independently and is isolated from the others to prevent interaction between channels.
    Select options
  • Compare

    900EN: 5-Port Ethernet Switch

    • 10/100Mbps
    • 15 to 36V DC power supply required
    • Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
    Acromag’s five-port Ethernet switch is specially designed for use in industrial applications. Rugged construction and a variety of security features ensure reliable operation under demanding conditions.
    Select options
  • Compare

    LNX-0702G: 7-Port Gigabit Ethernet with SFP Fiber Ports

    • 5-Port 10/100/1000TX and 2-port 100/1000 Fx SFP Slots
    • Auto MDI/MDI-X Function
    • 10Gbps Back-Plane
    Select options
  • Compare

    Terminal Block Replacements

    • Simplifies wiring connections on Acromag I/O Modules
    • Barrier strip or spring clamp terminal block kits
    • Provide safe and secure wiring connections
    Select options
  • Compare

    250T-DC, 350T-DC, 450T-DC: Analog Transmitter; AC-, DC- or Loop-Powered, DIN Rail-Mount

    • DC voltage or DC current input
    • DC voltage or DC current output
    • Loop or DC or AC power
    • Excellent accuracy and stability ensure reliable measurements in harsh industrial environments. Input isolated from output/power
    Select options
  • Compare

    270i: Input Loop-Power Isolator

    • 4-20mA DC input
    • 4-20mA DC output
    • 12 to 50V DC @ 20mA (loop-powered)
    • 1500V AC peak isolation DC prevents ground loops
    The 270i accepts a process current input and provides an isolated 4 to 20mA process current output signal. Power is received from the input signal current.
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms