Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing 1–16 of 44 results

  • Compare

    TT236: Current / milliVolt Input Two-Wire Transmitter

    • Multi-range ±20mA or ±500mV input
    • 4-20mA ouput (sink/source)
    • 12-32 V DC loop/local power
    The TT236 model is a space-saving two-wire transmitter that isolates and converts a DC current or low voltage input to a proportional 4-20mA control signal. A single unit supports both voltage and current input for extra flexibility. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    Select options
  • Compare

    DT236: Current / milliVolt Input Two-Wire Dual Transmitter

    •  Dual channels
    •  ±20mA, ±500mV inputs
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop power
    The DT236 model is a dual two-wire transmitter that isolates and converts DC current or low voltage inputs to proportional 4-20mA control signals. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short video highlighting the features of the DT236.  
    Select options
  • Compare

    NT2210: Ethernet Analog I/O Modules with 8 Differential Current Inputs, 2 Discrete I/O

    • 8 differential current inputs
    • 2 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2210 modules offer 8 current inputs and 2 limit alarms. Each input has true differential 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 4-20mA loops. Appending NTX expansion models can interface up to 32 differential current inputs on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2220: Ethernet Analog I/O Modules with 16 Single-ended Current Inputs

    • 16 single-ended current inputs
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2240 modules offer 16 current inputs. Each input supports bipolar and unipolar ranges with 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 4-20mA loops. Appending NTX expansion models can interface up to 64 current inputs on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2230: Ethernet Analog I/O Modules with 8 Differential Voltage Inputs, 2 Discrete I/O

    • 8 differential voltage inputs
    • 2 discrete I/O
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2230 modules offer 8 voltage inputs and 2 limit alarms. Each input has true differential 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 0-10V devices. Appending NTX expansion models can interface up to 32 differential voltage inputs on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2240: Ethernet Analog I/O Modules with 16 Single-ended Voltage Inputs

    • 16 single-ended voltage inputs
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2240 modules offer 16 voltage inputs. Each input supports bipolar and unipolar ranges with 16-bit A/D. NTE Ethernet models provide a compact network interface to monitor sensor levels or 0-10V devices. Appending NTX expansion models can interface up to 64 voltage inputs on a single IP address. Click here to watch a short video highlighting the features of the BusWorks NT Series.
    Select options
  • Compare

    NT2310: Ethernet Analog Output Modules with 8 Process Current Outputs

    • 8 process current outputs
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2310 modules offer 8 current outputs. Each output is driven by a 16-bit DAC. NTE Ethernet models provide a compact network interface to control 4-20mA loops. Appending NTX expansion models can interface up to 32 current outputs at a single IP address.
    Select options
  • Compare

    NT2320: Ethernet Analog Output Modules with 8 Process Voltage Outputs

    • 8 process voltage outputs
    • Ethernet I/O plus Expansion I/O
    • Multi-protocol support
    NT2320 modules offer 8 voltage outputs. Each output is driven by a 16-bit DAC. NTE Ethernet models provide a compact network interface to control voltage signal levels. Appending NTX expansion models can interface up to 32 voltage outputs at a single IP address.
    Select options
  • Compare

    XT1210: 8-Channel Differential Analog Current Input Module

    • 0-11mA, 0-20mA, 4-20mA, ±20mA, or 0-20 amps AC Input
    • 8 analog differential current input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1210 offers an isolated Ethernet network interface for up to eight differential current input channels. Differential inputs deliver better measurements and superior noise rejection.
    Select options
  • Compare

    VPM2000 Series: Loop-Powered Isolator / Alarm with Display

    • Loop-powered Process Meter
    • 4-20mA input/output
    • Solid-state relays
    • Non-incendive, intrinsically safe
    These loop-powered 1/8 DIN digital panel meters provide a convenient and informative display of any 4-20mA signal. A dual line display shows the process value on the top line and the units or a tag on the bottom line. Alternatively, you can display the input in one scale on the top line (e.g. height) and another scale on the bottom (e.g. volume). Click here to watch a short video highlighting the VPM2000 Series.
    Select options
  • Compare

    XT1220: 8-Channel Differential Analog Voltage Input Module

    • ±5V, ±10V, 0-5V, 0-10V Input
    • 8 analog differential voltage input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1220 offers an isolated Ethernet network interface for up to eight differential voltage input channels.
    Select options
  • Compare

    XT1230: 16-Channel Single-Ended Analog Current Input Module

    • 0-11mA, 0-20mA, 4-20mA, ±20mA, or 0-20 amps AC Input
    • 16 analog single-ended current input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1230 offers an isolated Ethernet network interface for up to to sixteen single-ended current input channels.
    Select options
  • Compare

    XT1240: 16-Channel Single-ended Analog DC Voltage Input Module

    • Input: ±5V, ±10V, 0-5V, 0-10V
    • 16 analog single-ended voltage input channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1240 offers an isolated Ethernet network interface for up to to sixteen single-ended voltage input channels.
    Select options
  • Compare

    XT1530: Analog Output & Digital I/O Ethernet Modules

    • 4 Analog DC Current Outputs
    • 4 Discrete Voltage I/O Channels
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1530 interfaces analog output and discrete I/O signals between measurement and control devices over Ethernet. Discrete I/O are individually configurable for input or high-side switched output operation.
    Select options
  • Compare

    VPM3000 Series: Universal Transmitter / Alarm with Display

    • Big, bright display
    • 4-20mA, ±10V, thermocouple, or RTD input
    • 4-20mA, Modbus serial, or alarm relay output options
    Acromag VPM3000 Vertuâ„¢ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications. Learn more about the VPM3000 by watching this short video.
    Select options
  • Compare

    XT1540: Analog Output & Digital I/O Ethernet Modules

    • 8 Analog DC Voltage Outputs ±10V (calibrated), ±5V (sub-range)
    • 4 Discrete Voltage I/O Channels 0-32V DC
    • 12 to 32V DC Power (2.8W)
    • Modbus TCP/IP, Ethernet/IP, Profinet
    • i2o® peer-to-peer available for Modbus TCP/IP only
    The XT1540 interfaces analog output and discrete I/O signals between measurement and control devices over Ethernet. Discrete I/O are individually configurable for input or high-side switched output operation.
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms