Acromag remote I/O modules feature signal conditioners and network I/O for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.
The DT233 model is a dual two-wire transmitter that isolates and converts millivolt or thermocouple sensor inputs to proportional 4-20mA control signals. Power is received from the output loop current.
Universal TC type J, K, T, R, S, E, B, N or ±100mV input
4-20mA ouput (sink/source)
12-32 V DC loop/local power
The TT233 model is a space-saving two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is received from the output loop current or a DC supply when using a three-wire connection.
Click here to watch a short AcroMaggie video highlighting the TT230 Series.
TT236: Current / milliVolt Input Two-Wire Transmitter
Multi-range ±20mA or ±500mV input
4-20mA ouput (sink/source)
12-32 V DC loop/local power
The TT236 model is a space-saving two-wire transmitter that isolates and converts a DC current or low voltage input to a proportional 4-20mA control signal. A single unit supports both voltage and current input for extra flexibility. Power is received from the output loop current or a DC supply when using a three-wire connection.
Click here to watch a short AcroMaggie video highlighting the TT230 Series.
The TT333 model is a space-saving four-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional control signal. DC current and voltage output are both supported on a single model.
Click here to watch a short video highlighting the TT330 Series.
DT236: Current / milliVolt Input Two-Wire Dual Transmitter
Dual channels
±20mA, ±500mV inputs
4-20mA outputs (sink/source)
7-32V DC loop power
The DT236 model is a dual two-wire transmitter that isolates and converts DC current or low voltage inputs to proportional 4-20mA control signals. Power is received from the output loop current or a DC supply when using a three-wire connection.
Click here to watch a short video highlighting the features of the DT236.
DT336: Current / milliVolt Input Four-Wire Dual Transmitter
Dual channels
±20mA, ±500mV inputs
0-20mA, ±10V outputs
6-32V DC local/bus power
The DT336 model is a four-wire dual transmitter that isolates and converts DC current or low voltage inputs to proportional control signals. Each channel supports DC current or voltage output.
VPM2000 Series: Loop-Powered Isolator / Alarm with Display
Loop-powered Process Meter
4-20mA input/output
Solid-state relays
Non-incendive, intrinsically safe
These loop-powered 1/8 DIN digital panel meters provide a convenient and informative display of any 4-20mA signal. A dual line display shows the process value on the top line and the units or a tag on the bottom line. Alternatively, you can display the input in one scale on the top line (e.g. height) and another scale on the bottom (e.g. volume).
Click here to watch a short video highlighting the VPM2000 Series.
DT237: Medium DC Voltage Input Two-Wire Dual Transmitter
Dual channels
0-10V, ±10V inputs
4-20mA outputs (sink/source)
7-32V DC loop power
DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT237 model is a two-wire dual transmitter that isolates and converts high-level DC voltage inputs to a proportional 4-20mA control signal. Power is received from the output loop current or a DC supply when using a three-wire connection.
Click here to watch a short video highlighting the features of the DT237.
DT238: High DC Voltage Input Two-Wire Dual Transmitter
Dual inputs
0±150V input
4-20mA outputs (sink/source)
7-32V DC loop/local power
The DT238 model is a two-wire dual transmitter that isolates and converts high-level DC voltage inputs to proportional 4-20mA control signals. Power is received from the output loop current or a DC supply when using a three-wire connection.
Click here to watch a short video highlighting the features of the DT238.
VPM3000 Series: Universal Transmitter / Alarm with Display
Big, bright display
4-20mA, ±10V, thermocouple, or RTD input
4-20mA, Modbus serial, or alarm relay output options
Acromag VPM3000 Vertu™ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications.
Learn more about the VPM3000 by watching this short video.
611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters
±100V DC, 0 to 100mA DC, 0 to 20A AC (with optional sensor) input
0 to 20mA, 0 to 10V DC output
10-36V DC power
Universal DC I/O transmitters with auto-configuration and self-ranging capabilities
These units receive DC current or voltage input signals, provide isolation, and output proportional DC current or voltage signals. With support for universal DC I/O ranges, 610T series transmitters provide a solution for a wide variety of isolation and signal conversion tasks.
These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels.
Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.