These modules provide an isolated Ethernet network interface for up to six input channels. Differential inputs eliminate ground noise and each terminal block includes a cold junction compensation (CJC) sensor for more precise temperature measurements. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability. Input Ranges: Ranges are selectable for a 3-channel group. Thermocouple (user-selectable type) Type J, K, T, R, S, E, B, or N DC Millivolts (user-selectable range) ±100mV or ±1V DC Network Communication: EtherNet/IP or Modbus TCP/IP 10/100Mbps with automatic data rate negotiation Power Requirement: 15 to 36V DC supply (2 Watts) required Approvals: CE/ATEX marked UL, cUL listed, Class I; Div. 2; Groups A, B, C, D EtherNet/IP, Modbus/TCP conformance tested

Performance Specifications

Input

Accuracy: Input            Input Range        Accuracy Type J:        -210 to   760°C          ±0.5°C Type K:       -200 to 1372°C          ±0.5°C Type T:       -260 to   400°C           ±0.5°C Type R:         -50 to 1768°C           ±1.0°C Type S:         -50 to 1768°C           ±1.0°C Type E:       -200 to 1000°C           ±0.5°C Type B:        260 to 1820°C           ±1.0°C Type N:      -230 to  -170°C           ±1.0°C Type N:      -170 to 1300°C           ±0.5°C Voltage:   ±100mV or ±1V DC     ±0.1% of span Cold Junction Compensation (CJC) Accuracy: ±0.5°C Noise Rejection: Normal Mode: Better than 40dB @ 60Hz Common Mode: Better than 140dB @ 60Hz Input Filter Bandwidth: -3dB at 3Hz, typical Input Conversion Rate: 80mS per channel

Environmental

Ambient Temperature and Humidity: Operating: -25 to 70°C (-13 to 158°F) Storage: -40 to 85°C (-40 to 185°F) Relative humidity: 5 to 95%, non-condensing Isolation: 1500V AC for 60 seconds or 250V AC continuous 3-way isolation between I/O, network, and power NOTE: i2o function only available on 6-channel Modbus TCP/IP modules.

Showing 17–32 of 41 results

  • Compare

    965EN: Ethernet Temperature Input Modules

    • 4 or 6-channel thermocouple/millivolt input
    • Ethernet/IP, Modbus TCP/IP, i2o peer-to-peer messaging
    $580$685
    Read more
  • Compare

    965PB: 4 or 6-Channel Input Profibus-DP Modules

    • Thermocouple or Millivolt Signals
    • 4 or 6 input channels, thermocouple or DC millivolts (user-selectable)
    • 12 to 36V DC  power
    • Profibus-DP, RS-485 network up to 12Mbaud
    $540$620
    Select options
  • Compare

    966EN: Ethernet Temperature Input Modules

    • 4 or 6-channel RTD/resistance input
    • Ethernet/IP, Modbus TcP/IP, i2o peer-to-peer messaging
    $580$685
    Read more
  • Compare

    966PB: 4 or 6-Channel Input Profibus-DP Modules

    • RTD or Resistance Signals
    • 4 or 6 input channels, Platinum 100 ohm, Nickel 120 ohm, Copper 10 ohm; 0 to 500 ohms resistance
    • 12 to 36V DC power
    • Profibus-DP, RS-485 network up to 12Mbaud
    $540$620
    Select options
  • Compare

    967EN: Ethernet Analog Input Modules

    • 8-channel differential current input
    • Modbus TCP/IP, 10/100Base-T(X), i2o peer-to-peer
    $390$730
    Read more
  • Compare

    968EN: Ethernet Analog Input Module

    • 8-channel differential analog voltage input
    • Modbus TCP/IP, i2o peer-to-peer communication
    $390$730
    Read more
  • Compare

    972EN, 973EN: Ethernet Analog Output Modules

    • 4 or 6-channel DC current or voltage output
    • Ethernet/IP, Modbus TCP/IP, i2o peer-to-peer messaging
    $580$685
    Read more
  • Compare

    972PB, 973PB: 4 or 6-Channel Output: DC Current or DC Voltage Signals

    • 0 to 1mA, 0 to 20mA, or 4 to 20mA DC Current Output; 0 to 1V, 0 to 5V or 0 to 10V DC Output
    • 12 to 36V DC Power
    • Profibus-DP, RS-485 network up to 12Mbaud
    $540$620
    Select options
  • Compare

    981EN, 982EN, 983EN: Ethernet Discrete I/O Modules

    • 12-channel discrete input and/or output
    • Ethernet/IP, Modbus TCP/IP, i2o peer-to-peer messaging
    $385$410
    Read more
  • Compare

    981PB, 982PB, 983PB: Profibus-DP 12-Channel Digital I/O

    • Active-Low Inputs, Sinking Outputs
    • 12 input channels, 0 to 35V DC range
    • 12 to 36V DC
    • High-speed RS-485
    $360$385
    Select options
  • Compare

    989EN: Ethernet Discrete I/O Modules with Counter/Timers

    • 16-channel discrete I/O
    • 8 counter/timers
    • Modbus TCP/IP communication
    $240$320
    Read more
  • Compare

    993EN: Ethernet Analog Input Modules

    • 16-channel single-ended analog current input
    • Modbus TCP/IP communication
    $580$835
    Read more
  • Compare

    994EN: Ethernet Analog Input Module

    • 16-channel single-ended analog voltage input
    • Modbus TCP/IP communication
    $580$835
    Read more
  • Compare

    BusWorks XT Connector Kit

    DIN rail bus power/excitation connector kit. Includes one DIN rail bus connector (1005-070), one left-side female connector terminal block (1005-220) and one right side male connector terminal block (1005-221).
    $25
    Select options
  • Compare

    Profibus-DP GSD Files

    • Download GSD files from the Software Tab
    Read more
  • Compare

    XT1110: 16-Channel Discrete Ethernet I/O Modules with Sinking Outputs

    • 16 discrete tandem input/output channels
    • Input: 0-32V DC, TTL thresholds
    • Output: 0-32V DC, open-drain, up to 250mA
    • Ethernet Communication: Modbus TCP/IP,  Ethernet/IP, Profinet, i2o® peer-to-peer, 10/100Base-T(X) PriorityChannel™ device determinism
    • Power Requirement: 12 to 32V DC (2.5W)
    $320
    Select options