New! 2 or 4-Wire USB-Configured Isolators and Transmitters

New! 2 or 4-Wire USB-Configured Isolators and Transmitters

Click here for details

The TT230 and TT330 series of space-saving, 2 or 4-wire transmitters and isolators are offered for a range of inputs with sink/source 4-20mA output compatibility. Using isolation, these transmitters protect from surges, noise, and ground loop errors.

New! USB-Configured High-Density Ethernet I/O

New! USB-Configured High-Density Ethernet I/O

Click here for details

The BusWorks XT series of Ethernet I/O modules support Modbus TCP/IP, Ethernet/IP, Profinet and i2o peer-to-peer communication protocols. They monitor and/or control up to 16 discrete or analog devices per unit with a variety of inputs and outputs supported.

Transmitter, Thermocouple Input, Loop-Powered

• TC type J, K, T, R, S, E, B, and N or ±100mV input

• 1500V isolation

• 4 to 20mA DC output

• USB-configured

The ST133 is a low-cost two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is received from the output loop current. The transmitter performs signal linearization, cold-junction compensation, and lead-break detection functions. Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.

• Easy setup and digital calibration via USB with Windows configuration software

• Flexible thermocouple or millivolt input ranges (TC Type J, K, T, R, S, E, B, N or ±100mV)

• 1500V input isolation

• 24-bit A/D microcontroller

• High accuracy, linearity, stability, and reliability

• Low temperature drift (<75ppm/°C)

• Fast response time (as low as 90ms)

• User selectable filtering (none, low, med., high)

• Supports reverse-acting (inverse) output

• Selectable upscale or downscale operation for sensor errors and lead-break detection

• Non-polarized output/power connection

• Mounts in DIN Form B sensor heads

• Shock (50g) and vibration (5g) resistant

• Optional DIN rail adapter

• Wide ambient operation (-40 to 80°C)

• Hardened for harsh environments

• CE compliant. UL/cUL Class 1 Div 2 Zone 2 approvals. Ex II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C certified.

Pricing and Order Information

Select country for Pricing
Part No. Description Price (in $USD)  
ST133-1600

Transmitter, thermocouple or millivolt input, CE compliant.

-
ST133-1610

Transmitter, thermocouple or millivolt input, CE compliant, UL/cUL Class 1 Division 2 Zone 2 approval, plus UL/cUL Class 1 Division 2 Zone 2 approval, plus Ex II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C certified.

-

Related Items

subscribe to newsletter

  • 877-214-6267