Features
• 8 analog voltage output channels
• Individual 16-bit D/A converters per channel
• 10µS settling time (100KHz throughput)
• Three output ranges: ±5V, ±10V, 0 to 10V (jumper-selectable)
• Two trigger modes (software or external trigger)
• External trigger output
• High load capability (5mA output current)
• 0 to 70°C (PMC230A-8) or -40 to 85°C (PMC230A-8E model)
The PMC230A is a drop-in replacement for the PMC230, please see the known differences document below for more information.
Known differences between the PMC230 and the PMC230A.